KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
9
DISPLAY OF POWER/STANDBY OR LAMP LED FLASH COUNT
PUSH OPEN
POWER/STANDBY
POWER
TIMER
LAMP
Indicators
Screen
- One flash is not us ed for s elf- diag nosis.
Number of times LED Flash
Lamp cove r
3 times
Fan
4 times
LED ON : 0.3 sec
LED OFF : 0.3sec
LED OFF
3.0 sec
LED OFF
3.0 sec
Example
Diagnosis
RELEASING THE POWER/STANDBY LED FLASH
Unplug the power cord from the outlet to temporarily stop the POWER/STANDBY lamp from fl ashing.
Self-Diagnostic Screen Display
For failures that are diffi cult to reproduce, or accompany occasional power off and/or picture mute, the Self-Diagnostic screen display is useful to
specify the cause.
VIEWING THE SELF-DIAGNOSTIC SCREEN
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume -
POWER
NOTE: This differs from the method of accessing service mode which is Volume +
Sample Self-Diagnostic Screen Display
SELF CHECK
1 :
LAMP_ERR
0
0
2 :
Lamp Temp Over
0
3 :
4 :
LAMP_ COVER
FAN_ERR
1
5 :
LAMP_DRIVER
6 :
LowB-ERROR
0
0
8 :
D_OVP
0
WDT
101 :
0
Name: KDF-50E2000
Serial: XXXXXXX
"1" is displayed when an error is detected one or more times
"0" is displayed when no error has been detected
NOTE: To refresh the Self Check menu when all the items are not displayed, press JUMP on the Remote Commander.