Retry Limitation by Remote/Power Key
16
Smart Core
Red LED
blinking
count
Error Name
Retry Permission Times
*1
Note
2x
MAIN_POWER
STDWN_RTRY_LIMIT_MAINP
OWR = 1
3x
DC_ALERT (5V)
STDWN_RTRY_LIMIT = 2
AUD_ERR
STDWN_RTRY_LIMIT = 2
4x
LD_ERR
STDWN_RTRY_LIMIT = 2
BCM_ERR
STDWN_RTRY_LIMIT = 2
5x
P_ID_ERR
STDWN_RTRY_LIMIT = 2
6x
BACKLIGHT
STDWN_RTRY_LIMIT = 2
7x
TEMP_ERR
STDWN_RTRY_LIMIT = 2
8x
4KBE_ERR
STDWN_RTRY_LIMIT = 2
Number of off/on action during the error
shutdown is recorded to
STDWN_OFFON_CNT.
*1) If STDWN_OFFON_CNT <= STDWN_RTRY_LIMIT, and STDWN_OFFON_CNT_MAIN_POWER <=
STDWN_RTRY_LIMIT_MAINPOWR, you can turn the set on by a remote/power key. At this time, if the error occurs again, the
STDWN_OFFON_CNT is incremented by 1.
*2) When the main micro operates normally for STDWN_OFFON_CLR = 60 minutes, STDWN_OFFON_CNT and
STDWN_OFFON_CNT_MAIN_POWER are cleared.
Number of off/on action for MAIN_POWER
shutdown is recorded to
STDWN_OFFON_CNT_MAIN_POWER.
SYS SET
2018/09/19 04:47:37 (GMT+09:00)
Summary of Contents for BRAVIA KD-55A9F
Page 2: ...SERVICE MANUAL COMMON OLED TV GN4UR CHASSIS Segment CS SYS SET 2018 09 19 04 47 37 GMT 09 00 ...
Page 115: ...CS65 CS55 Panel module Panel module 115 SYS SET 2018 09 19 04 47 37 GMT 09 00 ...
Page 116: ...SECTION 8 PANEL PEELING OFF METHOD OF FILM 116 SYS SET 2018 09 19 04 47 37 GMT 09 00 ...