9
Name and Function of Parts
Name and Function of Parts
Front Panel
a
Red tally light
Turns on when a red tally signal is received. When the CALL
button on the video camera, the MSU-1000 Master Setup Unit,
or the RCP-1000 series Remote Control Panel is pressed, the
light turns off if lit or turns on if not lit.
A supplied number plate can be attached (see following
diagram).
b
Yellow tally light
Turns on when a yellow tally signal is received.
c
Green tally light
Turns on when a green tally signal is received.
d
CCU number display
Displays the camera number specified in the menu of the CCU
for a system connection.
A number is not displayed when this unit is used as an
extension unit.
e
MENU control block
DISP/MENU lever and indicator:
Used to display the status
and menu. The indicator flashes when the menu is
displayed.
CANCEL/ENTER lever:
Used to cancel/enter settings when
the menu is displayed.
Control knob (rotary encoder):
Used to switch pages when
the status screen is displayed. Used to move the cursor
within a page and to change the setting of the selected
item when the menu is displayed.
Pushing the control knob has the same function as setting
the CANCEL/ENTER level to ENTER.
f
NMI LAN STATUS Indicators
Displays the status of NMI-LAN.
1:
Corresponds to SLOT 1 NMI LAN 1 to 2.
2:
Corresponds to SLOT 2 NMI LAN 1 to 2.
3:
Corresponds to SLOT 3/4 NMI LAN 1 to 2.
Green:
Normal state
Flashing green:
Network synchronization process is in
progress.
Off:
SFP+ module is not installed.
IP Live System Manager has been disconnected.
IP Live System Manager connection is being established.
Flashing red:
Not locked to network synchronization signal.
Signal reception is unavailable.
g
Status display indicators
REF IN (green):
Indicates presence of reference input signal.
UNLOCK (red):
Indicates operation is not synchronized to
input reference signal.
When connected to a CCU, REF IN and UNLOCK indicate
the lock status for the CCU.
NETWORK:
Displays the network system connection status.
On:
Indicates that an external control device (MSU-1000
Master Setup Unit or RCP-1000 series Remote
Control Panel) is connected when the CNS MODE
setting in <CNS SETTING> is set to BRIDGE.
Flashing:
Indicates that an external control device (MSU-
1000 Master Setup Unit or RCP-1000 series Remote
Control Panel) is not connected successfully when the
CNS MODE setting in <CNS SETTING> is set to
BRIDGE.
Off:
Indicates that the LAN cable is not connected or
network system connection parameters have not been
set when the CNS MODE setting in <CNS SETTING>
is set to BRIDGE.
The indicator is always off when CNS MODE is set to
LEGACY.
POWER
CAM
BPU
CCU
MENU
ENTER
DISP
REF IN
UNLOCK
COM ERROR
NETWORK
FAN STOP
SW
MENU LOCK
OFF
ON
CANCEL
OPTICAL CONDITION
MENU
USB connector (for service personnel)
MENU
ENTER
DISP
CANCEL
MENU
DISP/MENU lever and indicator
CANCEL/ENTER lever
Control knob