Monitor Function
When the destination to be monitored has been
specified on the terminal, the monitor display panel
automatically selects the source for that destination
when the monitor function is ON.
With the conventional system, the monitor signal is
returned to the input, as shown below, to monitor the
destination.
Such a process is not required for the monitor function,
which uses no extra crosspoint, and eliminates signal
delay in loopback.
An offset can be added to the automatically selected
source, which provides various monitoring
possibilities (c.g. monitoring an HD source with D1)
MONI
STATUS
PROT
LOCK
(CHOP)
BKS-R3219
14 15 16
13
LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4
MONI
STATUS
PROT
LOCK
(CHOP)
BKS-R1618
14 15 16
13
LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4
MONI
STATUS
PROT
LOCK
(CHOP)
BKS-R3219
Block 1
Block 3
Block 4
Block 2
MONI
STATUS
PROT
LOCK
(CHOP)
BKS-R1618
Block 1
Block 3
Block 4
Block 2
BKS-R3219
BKS-R1618
BKS-R3219
BKS-R1618
Level Control
You can assign levels to source/destination select
buttons, and use as the LEVEL select buttons.
Four Destination Control
You can divide source/destination select buttons to
four blocks, and assign destinations to each blocks.
Conventional monitor system
Example of source offset system
Source offset
Monitor display
panel
Standard system
D1 signal
HD to D1
Down conversion
HD signal
Monitor display panel
Overview