Page 1: ...S BUS INTERFACE BOARD BKP 7933 INSTALLATION MANUAL 1st Edition Revised 1 ...

Page 2: ... Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire...

Page 3: ...onitor Selection 1 12 E 1 7 3 Linking the MSU Camera Selection and the VE Monitor Selection 1 15 E 1 7 4 Switching the Video on the Preview Monitor with the RCP PREVIEW Switch 1 18 E 1 7 5 Executing RCP Assignment from Equipment Other Than MSU 1 22 E 1 7 6 Switching the MSU Camera Selection Externally 1 25 E 1 7 7 Changing the Camera Assignment Virtually 1 27 E 1 7 8 Using the Tally System 1 29 E ...

Page 4: ... 3 Modification of RCP 720 1 41 E 1 9 4 Modification of RCP 721 1 42 E 1 9 5 Modification of RCP 730 731 1 43 E 1 10 Using the BKP 7933 in the HD System 1 44 E 1 10 1 Controlling the Routing Switcher via the RS 422A Interface 1 44 E 1 10 2 Controlling a Waveform Monitor 1 46 E 1 11 Description on Internal Indicators 1 48 E ...

Page 5: ...vice based on the components parts such as schematic diagrams board layouts and spare parts lists assuming use of system and service engineers DVS V1616 A3232B V6464B RS1616 TC3232 A3232 BVS V3232 A3232 HDS V3232 Installation Manual for System Setup supplied with each unit It contains information on the initial settings of the software when installing the above units making up the digital router s...

Page 6: ......

Page 7: ...BKP 7933 is composed of the following items Main board IF 689 board 1 Rear panel with CN 1558 board 1 Installation manual 1 1 3 Installation Procedure This section explains briefly on installation procedures Refer to each section for details Installation procedure Section 1 Checking ROM Version 1 1 Checking ROM Version 2 Switch setting on the board 1 4 Setting Switches on the IF 689 Board 3 Instal...

Page 8: ...ROUP No S3 CNU GROUP No Set the CNU GROUP No so that it should be unique in a system Factory default setting 2 Setting Examples 1 When installing the BKP 7933 in the CNU 700 which is provided with the BKP 7930 2 When using the two CNU 700s which are provided with the BKP 7930 1 4 Setting Switches on the IF 689 Board CNU GROUP No 0 IF 480 CNU GROUP No 1 IF 480 IF 689 Set CNU GROUP No to 2 CNU GROUP...

Page 9: ...US ID No S12 S BUS ID No Set the station address for the unit on the standard S BUS data link n Set to numbers other than 0 1 and 255 Factory default setting 2 1 8 7 6 5 4 3 2 indicates the switch lever position 1 4 Setting Switches on the IF 689 Board Component side A side IF 689 board IF RX TX S BUS S BUS ID No S201 S5 S3 S12 CNU GROUP No 5 ...

Page 10: ...h have sharp edges Do not touch them with bare hands Pay careful attention when servicing 1 Loosen the two screws and remove the front panel of the CNU 700 2 Insert the IF 689 board in the fourth slot from the top 3 Attach the front panel to its original position Screw Screw Front panel IF 689 board 1 5 Installation ...

Page 11: ...933 1 5 2 Installing the Rear Panel 1 Remove the two screws and remove the blank panel 2 Install the rear panel with the two screws instead of the blank panel B3 x 5 B3 x 5 Blank panel Rear panel 1 5 Installation ...

Page 12: ...ctor Name Connection Connectors Conection Cable REMOTE S BUS BNC 75 Z BELDEN 8281 1 1 569 370 12 I O PORT D sub 50P Male 1 566 358 11 2 D sub for connector metal plating shell 50P 1 563 379 11 1 The BNC connector T bridge is available to connect the BELDEN 8281 cables BNC connector T bridge 1 764 805 11 2 The plug needs the following solderless contacts AWG 18 to 22 1 566 493 21 AWG 22 to 24 1 564...

Page 13: ...6 12 NC 13 NC 14 NC 15 OUT 28V 16 OUT 28V 17 SPARE 18 IN OUT EXTO 1 19 IN OUT EXTO 4 20 IN OUT EXTO 7 21 IN EXTI 2 22 IN EXTI 5 23 NC 24 NC 25 NC 1 6 Connection 1 6 Connection 17 1 50 34 18 33 Pin No I O Specifications 26 OUT EXT AN 1 27 OUT EXT AN 4 28 OUT EXT AN 7 29 NC 30 NC 31 OUT 5V 32 GND 5V 33 GND 28V 34 IN OUT EXTO 2 35 IN OUT EXTO 5 36 IN EXTI 0 37 IN EXTI 3 38 IN EXTI 6 39 NC 40 NC 41 NC...

Page 14: ...f one S BUS line is a maximum of 500 m when a BELDEN 8281 or the equivalent is used Be sure to terminate the BNC connector T bridge attached to the last machine of the S BUS line with a 75 Z terminator REMOTE S BUS BNC connector male BKP 7933 BELDEN 8281 cable shorter than 50 cm BNC Connector T bridge Secondary device Primary station 1 6 Connection ...

Page 15: ... TERMINAL IBM PC AT COMPATIBLES UNIVERSAL CONTROL UNIT BKS R3209 DIGITAL VIDEO SWITCHER DVS 7000 S BUS BNC VIDEO BNC T Bridge 75 Z Terminator PRIMARY STATION CCU 1 CCU 2 CCU 3 REMOTE CONTROL PANEL RCP 700 701 720 721 730 731 740 741 MASTER SETUP UNIT MSU 700 COLOR VIDEO CAMERA BVP 500 700 900 CAMERA CONTROL UNIT CCU 700A CAMERA COMMAND NETWORK UNIT CNU 700 with BKP 7933 S BUS INTERFACE REMOTE S BU...

Page 16: ... DESCRIPTION NAME GROUP O SET TIE LINES P CHANGE PASSWORD Q CHANGE CROSSPOINT R CALL SECONDARY STATION MAINTENANCE COMMAND T SET CLOCK U SELECT CONTROL MODE V SELECT WARNING DISPLAY ON W SYSTEM STATUS LOG X DISPLAY S BUS COMMUNICATION Y DISPLAY TABLE DATA Z SET UNIT DETECTABLE Ctrl_X QUIT SETUP MENU SONY ROUTING SYSTEM SETUP MENU BKP 7933 V1 00 STATION NUMBER 2 MODIFICATION COMMAND A SET UNIT LOCA...

Page 17: ... routing switcher system for an overview of level mapping Notes on Setting Up Perform the setup for the camera numbers that are actually connected If setup is performed for camera numbers that are not actually connected the response speed of the routing switcher may be slowed and the normal function may be hindered Be sure to set 0 for the camera numbers that are not actually connected When settin...

Page 18: ... to CAM5 the video signal on the VE monitor in front of RCP1 is switched at the same time from CAM1 to CAM5 n The contents that are set on this menu are reflected to the Setting status of the control system of the CNU 700 character display 1 7 Setting Up CCU 1 CCU 2 CCU 3 CCU 4 CCU 5 CCU 6 001 OUT 1 001 DESTINATION No 002 OUT 2 003 OUT 3 004 OUT 4 005 OUT 5 006 OUT 6 CCU 700A Digital Video Routing...

Page 19: ...NU DIGITAL ROUTING SWITCHER DVS V1616 SDI MONITOR for RCP RCP 700 Series CCA 5 CABLE CCU 550 with BKP 5972 S BUS BNC BELDEN 8281 CCU 700A with BKP 7311 CNU 700 with BKP 7933 MSU 700 CCU 700A with BKP 7311 RS 232C CHARACTER If using the ANALOG ROUTING SWITCHER BVS V3232 etc connect it to PIX or WF connector PIX 1 or WF 1 connector for the CCU 700A series VIDEO BNC PIX PIX WF PIX WF PIX WF CONTROL T...

Page 20: ... GROUP No SOURCE No DESTINATION No LEVEL No Camera No 0 1 0001 0001 1 0 2 0002 0002 0 3 0003 0003 0 4 0004 0004 0 5 0005 0005 0 6 0006 0006 1 7 0007 0007 1 8 0008 0008 1 9 0009 0009 1 10 0010 0010 1 11 0011 0011 1 12 0012 0012 F1 F2 F3 PgUp F4 PgDn Ctrl E RETURN TO MENU 2 Select either A ROUTER PIX1 ASSIGN or B ROUTER WF1 ASSIGN using the cursor key and press ENTER The illustration shows the displ...

Page 21: ... button is pressed the video signal of the selected camera can be output to the VE monitor This function is useful especially when the SDI signal is switched 0013 OUT 13 0014 OUT 14 Digital Video Routing Switcher PIX MSU1 MSU 700 PIX MSU2 CCU 1 CCU 2 CCU 3 CCU 4 CCU 5 CCU 6 001 DESTINATION No CCU 700A BVP 500 700 900 series SOURCE No SERIAL OUT IN 1 002 SERIAL OUT IN 2 003 SERIAL OUT IN 3 004 SERI...

Page 22: ...13 REMOTE 1 REMOTE S BUS REMOTE 3 IN 2 IN 6 SERIAL OUTPUT REMOTE RCP CNU SERIAL OUTPUT SERIAL OUTPUT REMOTE RCP CNU DIGITAL ROUTING SWITCHER DVS V1616 SDI MONITOR for MSU camera select CCU 550 with BKP 5972 S BUS BNC BELDEN 8281 CCU 700A with BKP 7311 CNU 700 with BKP 7933 MSU 700 CCU 700A with BKP 7311 VIDEO BNC PIX RS 232C CHARACTER PIX WF CONTROL TERMINAL IBM PC AT COMPATIBLES Connecting Periph...

Page 23: ...4 FOR MSU 2 0 3 0003 0000 FOR MSU 3 0 4 0004 0000 FOR MSU 4 0 5 0005 0000 FOR MSU 5 0 6 0006 0000 FOR MSU 6 0000 FOR MSU 7 1 7 0007 0000 FOR MSU 8 1 8 0008 0000 FOR MSU 9 1 9 0009 0000 FOR MSU 10 1 10 0010 0000 FOR MSU 11 1 11 0011 0000 FOR MSU 12 1 12 0012 0000 FOR MSU 13 0000 FOR MSU 14 0000 FOR MSU 15 0000 FOR MSU 16 F1 F2 F3 PgUp F4 PgDn Ctrl E RETURN TO MENU 2 Select either C ROUTER PIX2 ASSI...

Page 24: ...RS 232C CHARACTER PIX WF CONTROL TERMINAL IBM PC AT COMPATIBLES 1 7 4 Switching the Video on the Preview Monitor with the RCP PREVIEW Switch n RCP must be modified in order to use this function Refer to Section 1 9 Modification of RCP for details Description of Operation Set the menu as follows when you want to switch the video on the preview monitor with the RCP PRE VIEW switch The signal LINE IN...

Page 25: ...0 2 16 0000 2 17 0000 2 18 0000 3 19 0000 3 20 0000 3 21 0000 3 22 0000 3 23 0000 3 24 0000 F1 F2 F3 PgUp F4 PgDn Ctrl E RETURN TO MENU Setting from the S BUS Primary Station 1 Select the menu item Z BKP 7933 CONFIGURA TION and press ENTER 2 Select either E ROUTER PIX3 ASSIGN or F ROUTER WF3 ASSIGN using the cursor key and press ENTER The illustration shows the display that selects E ROUTER PIX3 A...

Page 26: ...ENU 2 Select the menu item H BKP 7933 MODE and press ENTER 3 Move the cursor key to the LINK MSU of 2 RCP PREVIEW SWITCH and press ENTER Notes when LINK MSU is selected Notes when LINK MSU is selected Notes when LINK MSU is selected Notes when LINK MSU is selected Notes when LINK MSU is selected It is linked to the MSU only that is connected to CNU 700 in which the BKP 7933 is installed It is not ...

Page 27: ...on mode MON ALT ALT1 with the UP DOWN switch Set the SET CANCEL switch to the SET position Each operation mode is described below MON The preview display appears only while the RCP PREVIEW switch is being pressed ALT The preview display appears when the RCP PREVIEW switch is pressed once and disap pears when it is pressed again ALT1 The preview display appears when the RCP PREVIEW switch is presse...

Page 28: ...etting cannot be made across two or more CNUs The setup data of the RCP assignment that is made here is saved in the BKP 7933 side n The contents of the settings that are made using this menu are reflected in the Setting status of the control system of the CNU 700 character display 1 7 Setting Up CCU 1 CNU 1 Top CCU 700A CCU RCP MATRIX shows an area where the SOUCE No and DESTINATION No cannot be ...

Page 29: ...BUS REMOTE REMOTE 3 IN 2 IN 6 SERIAL OUTPUT REMOTE RCP CNU SERIAL OUTPUT SERIAL OUTPUT REMOTE RCP CNU DIGITAL ROUTING SWITCHER DVS V1616 SDI MONITOR for RCP RCP 700 Series CCA 5 CABLE CCU 550 with BKP 5972 S BUS BNC BELDEN 8281 CCU 700A with BKP 7311 CNU 700 with BKP 7933 MSU 700 REMOTE CONTROL UNIT BKS R3202 CCU 700A with BKP 7311 VIDEO BNC PIX RS 232C CHARACTER PIX WF PIX WF PIX WF CONTROL TERMI...

Page 30: ...56 1 Ctrl E RETURN TO MENU Setting from the S BUS Primary Station 1 Select the menu item B SET UNIT LOCATION CCU RCP and press ENTER 2 Move the cursor key to the desired position to be changed and press ENTER The display enters the input mode 3 Input the SOURCE No DESTINATION No and LEVEL No using the numeric keys and press ENTER m Up to 96 in the range of 1 to 1024 can be selected and set to the ...

Page 31: ...select CCU 550 with BKP 5972 S BUS BNC BELDEN 8281 CCU 700A with BKP 7311 CNU 700 with BKP 7933 MSU 700 CCU 700A with BKP 7311 VIDEO BNC PIX REMOTE REMOTE CONTROL UNIT BKS R3202 RS 232C CHARACTER PIX WF CONTROL TERMINAL IBM PC AT COMPATIBLES 1 7 6 Switching the MSU Camera Selection Externally Description of Operation Set the menu as follows when you want to switch the MSU camera selection from a r...

Page 32: ...ATION No UP to 96 of the SOURCE No maximum number of cameras and up to 16 of the DESTINATION No maximum number of MSUs can be selected Any number in the range of 1 to 8 can be set to the LEVEL No This setting can be assigned to the respective level and can be mapped 1 7 Setting Up SET UNIT LOCATION MSU BKP 7933 V1 00 STATION NUMBER 2 MSU MATRIX Remote MSUs Camera Select SOURCE No DESTINATION No LE...

Page 33: ...R 2 Move the cursor key to the desired position to be changed and press ENTER The display enters the input mode SONY ROUTING SYSTEM SETUP MENU BKP 7933 V1 00 STATION NUMBER 2 MODIFICATION COMMAND A SET UNIT LOCATION CAM CCU B SET UNIT LOCATION CCU RCP C SET UNIT LOCATION MSU K RESET TO DEFAULT TABLE MAINTENANCE COMMAND Z BKP 7933 CONFIGURATION Ctrl D RETURN SET UNIT LOCATION CAM CCU BKP 7933 V1 00...

Page 34: ...3 CONFIGURATION BKP 7933 V1 00 STATION NUMBER 2 S BUS CONFIGURATION A ROUTER PIX1 ASSIGN B ROUTER WF1 ASSIGN C ROUTER PIX2 ASSIGN D ROUTER WF2 ASSIGN E ROUTER PIX3 ASSIGN F ROUTER WF3 ASSIGN G S BUS TALLY H BKP 7933 MODE Ctrl E RETURN TO MENU 2 Select H BKP 7933 MODE using the cursor key and press ENTER 3 Select SOURCE NAME of 3 CAMERA No with the cursor key and press ENTER 1 7 Setting Up BKP 7933...

Page 35: ...lly system as the response speed of the tally system may become slower m When you want to use the green tally lamp on the front panel of the CCU the CCU needs to be modi fied Refer to the maintenance manual separately available Refer to the installation manual of the Tally Interface Unit BKDS 7700 Section 3 2 4 Tally Configu ration for details of the tally system Connecting Peripheral Equipment CC...

Page 36: ...s ENTER The display enters the input mode 4 Input the SOURCE No using the numeric keys and press ENTER At this time assign the SOURCE No that has already been set by the system to the camera number m Any number in the range of 1 to 512 can be set Up to four group tallies can be set The installation shows the display on which the tally signal of the SOURCE No 0001 is assigned to the Camera No 1 1 7...

Page 37: ...SSIGN E ROUTER PIX3 ASSIGN F ROUTER WF3 ASSIGN G S BUS TALLY H BKP 7933 MODE Ctrl E RETURN TO MENU 6 Set the 1 SBUS TALLY SYSTEM to the ON position using the cursor key and press ENTER n The tally system can be turned on and off using this menu 1 7 Setting Up BKP 7933 CONFIGURATION BKP 7933 V1 00 STATION NUMBER 2 1 SBUS TALLY SYSTEM OFF ON 2 RCP PREVIEN SWITCH INDEPENDENCE LINK MSU 3 CAMERA No CNU...

Page 38: ... 7933 V1 00 STATION NUMBER 2 MODIFICATION COMMAND A SET UNIT LOCATION CAM CCU B SET UNIT LOCATION CCU RCP C SET UNIT LOCATION MSU K RESET TO DEFAULT TABLE MAINTENANCE COMMAND Z BKP 7933 CONFIGURATION Ctrl D RETURN BKP 7933 CONFIGURATION BKP 7933 V1 00 STATION NUMBER 2 S BUS CONFIGURATION A ROUTER PIX1 ASSIGN B ROUTER WF1 ASSIGN C ROUTER PIX2 ASSIGN D ROUTER WF2 ASSIGN E ROUTER PIX3 ASSIGN F ROUTER...

Page 39: ... to the Factory Default Values 1 Establish the following setup of the switch S2 on the IF 689 board depending upon the type analog digital of routing switcher S2 1 When the analog routing switcher BVS V3232 is used ON When the digital routing switcher DVS V1616 is used OFF S2 2 to S2 8 OFF Factory default setting All OFF 2 Set the switch S5 on the IF 689 board as shown below S5 1 to S5 3 OFF S5 4 ...

Page 40: ... 12 cam CCA 5 CABLE CCU 1 to 12 CNU 700 with BKP 7930 13 cam 24 cam MSU 700 CCU 700A with BKP 7311 CHARACTER VIDEO BNC REMOTE RCP CNU SERIAL OUTPUT CCU 700A with BKP 7311 SERIAL OUTPUT REMOTE RCP CNU CCU 550 with BKP 5972 SERIAL OUTPUT REMOTE RCP CNU CCU 550 with BKP 5972 PIX PIX WF CONTROL TERMINAL IBM PC AT COMPATIBLES 1 7 12 Connecting 13 or More Cameras An example of connecting 13 or more came...

Page 41: ...key Return key Space bar One space is made 1 8 1 Installing the BZR 10 BZR 10 operates on the MS DOS version 6 2 or in the DOS mode of Windows95 Use the IBM PC AT compatible personal computer in which the terminal software has been already installed 1 Insert the BZR 10 floppy disk abbreviated as FD hereafter in an FD drive of a personal computer 2 Select the FD drive Which is A drive in this docum...

Page 42: ...nabled When the Enter key is pressed again question mark disappears 9 Use the Ctrl e key combination Next use the Ctrl x key combination Return to the menu screen of the primary station 10 Quit the terminal software 11 Insert the formatted FD in the disk drive of the personal computer 12 Type as follows C a A Type a or a1 n a or a1 is the command to start up the backup software Type a or a1 accord...

Page 43: ... the menu screen of the primary station 18 Select Z SET UNIT DETECTABLE and return the settings of the secondary stations to the previous settings 19 Quit the terminal software Routing Switcher Data Backup Software BZR 10 Vl 10 1 RECEIVE from primary station 2 EDIT 3 SEND to primary station 9 QUIT Select a menu item 1 2 3 9 From primary station Receive Menu 1 All the data of primary station 2 The ...

Page 44: ...e baud rate is 38400 bps 3 Type 3 at the Function menu 3 SEND is selected The display changes to the Execution menu screen 4 To restore the data of the BKP 7933 type 2 2 The data of secondary stations is selected 5 Type 9 twice 9 Quit is selected The backup mode is terminated Routing Switcher Data Backup Software BZR 10 V1 10 1 RECEIVE from primary station 2 EDIT 3 SETD to primary station 9 QUIT S...

Page 45: ...e Center ROM Version RCP 700 701 IC8 MPU 92 Ver 2 00 or higher RCP 720 721 730 731 IC10 MPU 79 Ver 2 00 or higher 1 9 2 Modification of RCP 700 701 n After this modification is implemented the PREVIEW switch of the RCP 701 does not turn on even if it is pressed Required Parts Description Sony P N Q ty Diode 1SS300 TE85L 8 719 024 81 1 Jumper wire _ _ Modification Procedure SW 752 Board 1 Remove Q3...

Page 46: ...1 40 E BKP 7933 1 9 Modification of RCP SW 752 BOARD SW 752 BOARD ...

Page 47: ...N Q ty Jumper wire _ _ Modification Procedure 1 Connect the two jumper wires by soldering SW 754 board Between pin 6 CN3 and D25 cathode 1 Between pin 5 CN3 and pin 2 S24 2 2 Disconnect CN101 CN 1187 board Setting Switch on MPU 92 Board S4 7 MPU 79 board ON 1 9 Modification of RCP ...

Page 48: ...5 SW 755 board 2 Connect a metal resistor 82 Z to the soldering land of R10 by soldering 3 Connect the four jumper wires by soldering to the following locations SW 755 board Between pin 3 CN2 and D25 cathode 1 Between pin 4 CN2 and pin 2 S24 2 Between pin 2 CN2 and pin 3 S36 3 Between pin 1 CN2 and R55 4 4 Disconnect CN101 CN 1187 board Setting Switch on MPU 92 Board S4 7 MPU 79 board ON 1 9 Modif...

Page 49: ...or Chip Metal 82 Z 1 216 625 11 1 Modification Procedure SW 893 Board 1 Remove soldering of R1 R2 R3 and R12 2 Connect metal resistors 0 Z to the soldering land of R4 R6 and R7 by soldering 3 Connect metal resistors 82 Z to the soldering land of R5 by soldering Setting Switch on MPU 92 Board S4 7 MPU 79 board ON 1 9 Modification of RCP ...

Page 50: ...ssignment referring to the following description Required Parts Description Q ty Remarks Jumper wire 1 _ RS 422 harness 30P 30P 1 Supplied with HKCF 700 ROM MSU 700 ROM 25 board 1 Supplied with HKCF 700 REMOTE RCP CNU REMOTE CCU CNU SERIAL OUTPUT I O PORT PIX CCA 5 CABLE CCA 5 CABLE OPTICAL FIBER CABLE MASTER SETUP UNIT MSU 700 HD COLOR CAMERA HDC 700A HD CAMERA CONTROL UNIT HDCU 700A CAMERA COMMA...

Page 51: ...ween pin 2 and pin 3 The command interface is set to RS 422A S901 4 ON S901 5 OFF S901 6 OFF The baud rate is set to 38 4 k bps n There can be a case that the optional IF 480 board has already been installed to the second slot In such a case setting the switches on the IF 480 board in the second slot is not necessary Switches are invalid even though they are set ROM Replacement of the MSU 700 Repl...

Page 52: ...is installed A waveform monitor cannot be controlled by the MSU that is connected to the optional IF 480 board CNU IF board BKP 7930 1 Set the switch S2 2 on the IF 689 board to OFF When it is set to OFF remote control mode of the waveform monitor is selected 2 Set the switch S2 3 on the IF 689 board in accordance with a waveform monitor in use HD ANALOG system waveform monitor such as Tektronix 1...

Page 53: ...R MALE WIRING SIDE GND Connection The wiring diagram of the cable connecting the I O PORT connector and a waveform monitor is shown below The wiring diagram can change depending on the system of the waveform monitor HD ANALOG system 8 15 7 14 6 13 5 12 4 11 3 10 2 9 1 1 2 3 34 35 18 17 50 33 32 19 20 4 21 36 37 RECALL 0 THREE RECALL 1 STORE CH 1 CH 3 GND A B ONE TWO LINE FIELD RGB EN CH 2 BOTH 50P...

Page 54: ...ied to the IF 689 board D402 S BUS RX Green Lights when the serial data is received from the REMOTE S BUS connector D403 S BUS TX Green Lights when the serial data is transmitted to the REMOTE S BUS connector Component side A side IF 689 board D1 D402 D403 IF RX TX S BUS S BUS ID No CNU GROUP No 5 1 11 Description on Internal Indicators ...

Page 55: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Page 56: ...Printed in Japan Sony Corporation 2000 5 08 Communication System Solutions Network Company 1998 BKP 7933 SY J E 3 201 655 02 ...