19
BKM-62HS HD SDI/SDI Input Adaptor
Assigning input signals to connectors
After installing the BKM-62HS in the video monitor, make
necessary settings for each input channel using the INPUT
CONFIGURATION menu of the monitor. The BKM-
62HS may not work properly without the settings.
For details on INPUT CONFIGURATION menu, see “
C
Setting the Input Configuration – INPUT
CONFIGURATION Menu” in the Operation Manual for
your monitor.
Specifications
General
Voltage
+5 V, ±6 V (supplied from the monitor)
Power consumption
5.5 W max.
Operating conditions
Temperature
0°C to 35°C (32°F to 95°F)
Optimum temperature
20°C to 30°C (68°F to 86°F)
Humidity
0% to 90% (no condensation)
Pressure
700 hPa to 1060 hPa
Storage and transport conditions
Temperature
–10°C to 40°C (14°F to 104°F)
Humidity
0% to 90%
Pressure
700 hPa to 1060 hPa
Maximum external dimensions (w/h/d)
25 × 256 × 248 mm
(1 × 10
1
/
8
× 9
7
/
8
inches)
Mass
approx. 910 g (2 lb)
Input/output connectors
Digital input
BNC × 2 (75 ohm), with monitor
output
Signal characteristics
HD digital component signals
HD SDI reception characteristic:
Input impedance
75 ohm unbalanced
Data rate
1.4835 Gbps to 1.485 Gbps
Monitor output:
Output signal amplitude
800 mVp-p ±10%
Output impedance
75 ohm unbalanced
Frequency characteristics
Y: 48 Hz to 30 MHz ±1 dB
P
B
/P
R
: 48 Hz to 30 MHz ±1 dB
G/B/R: 48 Hz to 30 MHz ±1 dB
Chrominance signal/luminance signal
Delay time error
10 nsec max.
Gain error
3% max.
Aperture compensation
6 dB min. (25 MHz)
Quantization
10 bits/sample
Transmission distance
100 m (approx. 328 ft) max. (When
using 5C-FB coaxial cables (Fujikura,
Inc.) or equivalent.)
Return loss
–15 dB max. (5 MHz to 1.485 GHz)
SD digital component signals
Sampling frequency
Y: 13.5 MHz
R-Y/B-Y: 6.75 MHz
Frequency characteristics
Y: 50 Hz to 5.75 MHz ±1 dB
R-Y/B-Y: 50 Hz to 2.75 MHz ±1 dB
Chrominance signal/luminance signal
Delay time error
30 nsec max.
Gain error
5% max.
Aperture compensation
6 dB min. (5 MHz)
Quantization 10
bits/sample
Transmission distance
200 m (approx. 656 ft) max. (When
using 5C-2V coaxial cables (Fujikura,
Inc.) or equivalent.)
Return loss
–15 dB min. (5 to 270 MHz)
Accessories supplied
Operation Manual (1)
Design and specifications are subject to change without
notice.
Summary of Contents for BKM-61D
Page 26: ...26 ...