1-33 (E)
1-12. Multi Channel Setting
To control two or more DME-3000/7000 from one control
panel, each DME-3000/7000 must be recognized on the
control panel by respective channel numbers. This is
called a physical channel.
The physical channel is set by the following switches.
DME-3000
: S301-7 and S301-8 on CPU-114 board
Physical channel
S301-7
S301-8
CH1
OFF
OFF
CH2
OFF
ON
CH3
ON
OFF
CH4
ON
ON
DME-7000
: S801-6 to S801-8 on CPU-196 board
Physical channel
S801-6
S801-7
S801-8
CH1
OFF
OFF
OFF
CH2
OFF
OFF
ON
CH3
OFF
ON
OFF
CH4
OFF
ON
ON
CH5
ON
OFF
OFF
CH6
ON
OFF
ON
CH7
ON
ON
OFF
CH8
ON
ON
ON
n
Set their different physical channels to two or more DME-
3000/7000.
The physical channel is not necessarily same as the logical
channel number displayed on the control panel. The
physical channel and its corresponding logical channel can
be assigned by the setup menu.
n
For details of the setup menu, refer to the optional User’s
Guide BZDM-3020 or BZDM-7020.
n
If the channel number is not assigned, a message “Commu-
nication Error” displays on the menu monitor. This
message shows that there is obstruction in communication
between control panel and processor.
1-12. Multi Channel Setting