UXP X
2014-12-05
33
/ 55
IxD Blueprint
UXC
CONFIDENTIAL
ASW219 ASW218 ASW217 ASW216 ASW170 ASW169 ASW168
14.2
Remote mode - LED and vibration feedback
When connected A1II enters remote mode if the user taps within 5000 ms
after key short press. Remote mode has a time out 10 000 ms after the last
tap sequence. Key short or long press will exit remote mode directly. A1II goes
back to idle or control mode depending on previous mode.
Double and triple tap must have less than 500 ms between the taps.
Single, double and triple tap have corresponding vibration feedback with a
500 ms delay ensuring that the whole tap sequence was finished.
LED C
LED A
LED B
100 ms
14.2.1
LEDs in Remote mode
14.2.2
Vibration feedback
after single tap
14.2.3
Vibration feedback
after double tap
14.2.4
Vibration feedback
after triple tap
100 ms
LED C
LED A
LED B
100 ms
200 ms
100 ms
LED C
LED A
LED B
100 ms
200 ms
100 ms
200 ms
Remote mode up to 10 000 ms after the last tap
Tap within 5000 ms from key short press
LED C
LED A
LED B