45
4 Leak test
5 Operation and storage
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas
tightness check must be performed at the installation site because of possible mishandling in
shipment or excessive pressure being applied to the heater.
• Make a soap solution of one part liquid detergent and one part water. The soap solution can
be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
• The heater must be checked with a full cylinder.
• Make sure the safety control valve is in the
OFF
position.
• Turn the gas supply ON.
• In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply
on and recheck.
•
Never leak test while smoking!
To turn on the heater:
1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the control knob to
Hi
position.
3. Press and hold the control knob for 30 seconds. While holding down the control knob, press
the igniter button several times until the pilot flame lights. Release the control knob after the
pilot flame has lighted up.
• If a new tank has just been connected, please allow at least one minute for the air in the
gas pipeline tp purge out trough the pilot hole.
• When lighting the pilot flame make sure that the control knob is continuously held down
while pressing the igniter button. The control knob can be released after the pilot flame
lighted up.
• Pilot flame can be watched and checked from the small round window with sliding lid
located at the bottom of the flame screen (to the left or right side of the controller).
• If the pilot flame does not light or goes out, repeat step 3.
4. After the pilot flame has lighted up, turn the control knob to maximum position and leave it
there for 5 minutes or more before turning the knob to the to desired temperature position.
EN
Summary of Contents for 30310288
Page 1: ...Artikel Nr VLAM 30310288 VLAM GARTENFLAMME Bedienungsanleitung...
Page 14: ...VLAM CHAUFFAGE Mode d emploi Article nr VLAM 30310288 FR...
Page 27: ...VLAM RISCALDATORE PER ESTERNI Manuale dell utente Nr articolo VLAM 30310288 IT...
Page 40: ...VLAM PATIO HEATER Manual Article Nr VLAM 30310288 EN...