background image

- 9 -

KEY PAD INFORMATION

7

2ND

Circle

 is used to find the circumference 

and area of a known diameter of a circle.

4

2ND

Arc

 is used to find the length of an arc 

after diameter and angle are entered.

2ND

2

Fixed Fraction

 mode is used to select a

desired fraction result.

Triangle Keys

Pitch

Pitch

 is used to calculate the pitch (slope)

of a right triangle. Once pitch entered 

continued pressing of pitch key will cycle

through Angle, Rise and Ratio.

Run

Run

 is used to enter or calculate.

To calculate the run, you must enter any 

two of the following: rise, pitch, diagonal 

(length).

Rise

Rise

 is used to enter or calculate.

To calculate the rise, you must enter any

two of the following: run, pitch diagonal 

(length)

/ 2

/ 64

- 10 -

KEY PAD INFORMATION

Diag

 

Diagonal

/Length is used to enter or 

calculate. To calculate the diagonal/length,

you must enter any two of the following: 

Rise, Run, Pitch.

Diag

2ND

Raked Wall

 is used to figure stud lengths

in a raked wall. Given pitch, rise and/or 

run continuous pressing of Rake function

will show descending stud lengths.

H/V

Hip/Valley

 is used to find the lengths of 

regular or irregular hip/valley rafters.

When used alone it shows the regular 

hip/valley length. If an irregular pitch  

[2ND]

[H/V]

  is entered first, then the irregular 

hip/valley will be shown.

H/V

2ND

Irregular Pitch

 is used to change the 

regular pitch value for determining lengths

of irregular hip/valley and jack rafters.

To recall press  

[2ND]  [H/V]

Jack

Jack

 is used once the length of the Hip 

(or valley) is found. Continuous entry will

display the descending sizes of the jack 

rafters until “0” is displayed. These 

calculations will use a standard on center

stud spacing of 16" unless otherwise 

specified. To change the OC default enter

desired dimension prior to pressing 

[Jack]

.

- 11 -

KEY PAD INFORMATION

Jack

2ND

Irregular Jack

 is used once the length of

the Hip(or valley) rafter is found.

Entry of  

[2ND] 

 

[Jack]

  followed by 

successive entry of  

[Jack]

  will display 

the descending sizes of the irregular hip

(or valley) until “0” is displayed.

Continuing to press  

[Jack]

  will show the

display the regular jack rafters.

Rise

2ND

 

Stair

 is used to calculate the number or 

risers, actual riser heights, riser 

under/overage, number of treads, tread 

overage/underage, stringer/carriage and 

inclination angle-Rise and/or Run is 

required. The default riser height of 71/2"

can be changed by pressing desired height

followed by  

[2ND]

  

[Rise] .

Run

2ND

Tread

 is used to calculate the width of the

tread. The default tread width of 10" can 

be changed by pressing desired width 

followed by  

[2ND]

  

[Run] 

.

Summary of Contents for DT220

Page 1: ...Weight Conversions 17 Liquid Conversions 17 Temperature Conversion 17 Paperless Tape Review 18 19 EXAMPLE PROBLEMS 20 35 Complex Area 20 Carpentry Rough Opening 21 Carpentry Joist Numbers 21 CONTENTS...

Page 2: ...ys Percent is used to find a given percentage of a number 6 2ND X2 is used to take the square quantity multiplied by itself of the number on the display No operation is performed if the square of an a...

Page 3: ...ter and convert pounds lbs 2ND kg Use to enter and convert kilograms DryOz Dry Oz use to enter and convert Dry Ounces DryOz 2ND grams Use to enter and convert grams Dimension Keys Mile Mile Use for en...

Page 4: ...alley length If an irregular pitch 2ND H V is entered first then the irregular hip valley will be shown H V 2ND Irregular Pitch is used to change the regular pitch value for determining lengths of irr...

Page 5: ...4 5 Enter 7 Ft 0 3 64 INCH Feet 32 4 1 2 3 4 5 Enter 2 5 Inch 5 2 Inch 4 5 14 GETTING STARTED DEFAULT SETTINGS Reduced Fraction Mode Your calculator is set to Reduced Fraction mode which give the mos...

Page 6: ...isplayed Convert 10 pounds 10 lbs 10 LB To kgs 2ND kg 4 535924 KG Liquid Conversions Key Sequence Result Displayed Convert 10 Gallons 10 Gal 10 GL To Liters 2ND Gal 37 85412 L Temperature Conversion K...

Page 7: ...4 Tape 04 6 Tape 05 7 Tape 06 10 19 GETTING STARTED To review in the reverse direction Note If more than one series of calculations have been performed the Paperless Tape will only review the last se...

Page 8: ...dd to memory Find Area of c Enter Feet Inch 5 3 0 3 5 3 Answer 87 5 SQFt Press M to store in memory Press RCL RCL to recall 125 total SQ Ft then multiply by depth Inch 4 3 5 Answer 41 66667 CU Ft To c...

Page 9: ...nd you require shorter risers 5 and wider treads 3 for physically challenged user Operation Reset Enter CE CLR CE CLR Display 0 Operation Enter Height Enter Rise Feet 3 Display RISE 3 Ft 0 INCH Operat...

Page 10: ...c foot of lumber conversions can only be done to and from other cubic measurements Circle Solutions After entering the diameter of a circle the Circle function is used to find the circumference and ar...

Page 11: ...12 thus a 4 12 roof has a SLOPE of 4 when entering SLOPE always use inches In Metric pitch is expressed in millimeters over 1 000 millimeters of run Enter Display Pitch Inch 4 PTCH 4 INCH Run Feet In...

Page 12: ...d on center spacing applies to main roof and 18 on center spacing applies to hip roof Fix Fraction to 8ths Operation Change Fixed Fraction Key Sequence 8 2 2ND 2ND Display Fix 0 Operation Run Key Sequ...

Page 13: ...re possible Don t leave the calculator on when not in use NOTE To save the battery calculator will turn off automatically after 10 12 minutes of inactivity at which time the displayed value and memory...

Page 14: ...rmal Size Actual Size S4S 1 x 2 3 4 x 1 1 2 1 x 3 3 4 x 2 1 2 1 x 4 3 4 x 3 1 2 1 x 6 3 4 x 5 1 2 1 x 8 3 4 x 7 1 4 1 x 10 3 4 x 9 1 4 1 x 12 3 4 x 11 1 4 2 x 2 1 1 2 x 1 1 2 2 x 3 1 1 2 x 2 1 2 2 x 4...

Page 15: ...are designed to provide reasonable protection against harmful interference in a residential installation This device generates uses and can radiate radio frequency energy and if not used in accordance...