MNT-PTX-150
Doc Ref :
150-100
Issue
:
1.00
Page :
2
SONIK - 1999
IV.
Click ”Modem” button to configure dial-out parameters and PMD board.
V.
Click ”Alarms” button to set alarm limits for RF power, High VSWR,
Temperature, Voltage and High Current.
VI.
Click ”Read” or ” Update” button to Read or Update Transmitter Parameter
Settings.
VII.
Click ” Diagnostics” button to Diagnose the transmitter with real-time
parameters (Forward Power, VSWR, Temperature, Power Voltage, PA Current
and PA driver power) monitoring.
VIII.
Click ”Dial Remote” button to dial remote transmitter with an internal dialer.
Before dialing, please be sure to set the dial MODEM parameters using the
following AT commands: ATS0=1, AT&D0, AT&K0, AT&W0. Then, select item
”Modem Setup” or ”Dialer Setup” from ”Local Setup” menu to setup local dial
MODEM and dialer.
IX.
Click ”Load” or ”Save” button to Load/Save the current transmitter settings
from/to a local file.
X.
Click ”Terminal” button to access the terminal program.