10

4      Technical Specification

Technical Specifications

Physical Specification

Power Supply:  

Plug-top power supply providing 6V at 1A, 

 

with 4 international wall adapters (UK, EU, 

 

US and AUS) and 5m lead to bare ends. 

Power Input:  

5-7V DC

40cm Sign: 

500mA max

Input Connector: 

4 way screw terminal block

Control Inputs: 

2 x pull-down to 0V

Perspex Dimensions:  Single: 40cm (W) x 8cm (H)

Overall Sign Dimensions: 

 

LD-20F1   

333mm x 129mm x 60mm 

LD-40F1   

527mm x 129mm x 60mm 

LD-40F2   

527mm x 129mm x 60mm

Equipment Type
Single Flush Mounting Signs (20cm):

LD-20F1REC 

20cm ‘RECORD’ Sign

LD-20F1ONA 

20cm ‘ON AIR’ Sign

LD-20F1MCL 

20cm ‘MIC LIVE’ Sign

Single Flush Mounting Signs (40cm):

LD-40F1REC 

40cm ‘RECORD’ Sign

LD-40F1ONA 

40cm ‘ON AIR’ Sign

LD-40F1MCL 

40cm ‘MIC LIVE’ Sign

LD-40F1PHN 

40cm ‘PHONE’ Sign

LD-40F1TRF 

40cm ‘TRAFFIC FLAG ON’ Sign

LD-40F1ADB 

40cm ‘AD BREAK’ Sign

LD-40F1REH 

40cm ‘REHEARSAL’ Sign

LD-40F1DOR 

40cm ‘DOOR’ Sign

LD-40F1OBT 

40cm ‘OBIT’ Sign

LD-40F1NOE 

40cm ‘NO ENTRY’ Sign

LD-40F1EXIT 

40cm ‘EXIT’ Sign

LD-40F1SIL 

40cm ‘SILENCE PLEASE’ Sign

LD-40F1MET 

40cm ‘MEETING IN PROGRESS’ Sign

LD-40F1INT 

40cm ‘INTERVIEW IN PROGRESS’ Sign

 Twin Flush Mounting Signs (2 x 20cm):

LD-40F2TX-REH 

2 x 20cm ‘TX’ & ‘ REH’ Sign

LD-40F2ONA-MCL 

2 x 20cm ‘ON AIR’ & ‘MIC LIVE’ Sign

 Mounting Kits:

LD-KE1 

End Mounting Kit For 40cm Or 20cm Flush 

 Mounting 

Signs

LD-IT 

LED Sign End Mounting Installation Tool

LD-KC1  

SignalLED Ceiling or Desk Mount Bracket (Pair)

Weights & Boxed Dimensions:
Sign Type 

Width   Depth  Height  Gross Weight  Net Weight

 

(cm) 

(cm) 

(cm)   

(cm)  

(kg)

LD-20F1 style signs 

39 

20 

11 

1.0 

0.65

LD-40F1 style signs  

60 

20 

11 

1.1 

0.75

LD-40F2 style signs  

60 

20 

11 

1.1 

0.75

Note : 

Weights are approximate and based on a sign supplied with the PSU.

Summary of Contents for SignalLED Series

Page 1: ...Manufacturers of audio video products for radio TV broadcasters SignalLED Studio Illuminated Signs HANDBOOK...

Page 2: ...sent a commitment on the part of the vendor Sonifex Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual No part of this...

Page 3: ...tions 10 Appendix 1 11 LD KE1 SignalLED Conversion Kit Single Flush Mount to End Mount 11 Figures Fig 1 1 Australia Certificate of Approval v Fig 1 2 CB Certificate of Approval v Fig 1 3 CE Certificat...

Page 4: ...uk y Internet www sonifex co uk As standard Sonifex products are supplied with a 1 year back to base warranty If you register the product online you can increase your product warranty to 2 years and...

Page 5: ...when the product has been registered at the Sonifex website when the Warranty Term is 24 months from the date of despatch the Contract means the quotation these Conditions of Sale and any other docum...

Page 6: ...for any loss of profits or other economic losses The Company accordingly excludes all liability for the same e At the request and expense of the Purchaser the Company will test the Goods to ascertain...

Page 7: ...roduct is shipped with the following equipment so please check to ensure that you have all of the items below If anything is missing please contact the supplier of your equipment immediately Item Quan...

Page 8: ...imited hereby certify that the following product with serial number shown has been designed and manufactured in accordance with the following specifications EMC EN 55103 1 1997 Electromagnetic Compati...

Page 9: ...SignalLEDs is UL EC and CC approved For a more detailed view of the certificates please check online at http www sonifex co uk signalled index shtml Fig 1 1 Australia Certificate of Approval Fig 1 2...

Page 10: ...f the hazardous substances identified in the European Union s Restriction of Hazardous Substances RoHS directive The manufacturing processes include the assembly of purchased components from various s...

Page 11: ...the wall mount moulding The LED sign should be mounted on a firm solid surface The sign is supplied with a mounting kit comprising 2 x wall plugs and 2 x large flange screws Note You ll need the foll...

Page 12: ...sed to hold the sign in place while you connect the power and signal cables The cable retention clips can be used to hold the cables in the sign See information on connecting the Power and Signal cabl...

Page 13: ...tic moulding must be opened To open the door push the clip towards the sign and pull down on the small lip see Fig 2 5 Do not attempt to remove the door from the end moulding Access to the connection...

Page 14: ...ent that a power supply can supply will be affected by the type of wiring used and its length i e it s total impedance For example using bell wire presents too high an impedance and should not be used...

Page 15: ...er contact closure between Pins 4 3 0V of the connector block When the power and signalling connections have been made close the access door by pressing the clip back to its original position It will...

Page 16: ...nect pin 1 to 0V to select input 1 Connect pin 4 to 0V to select input 2 For each of the 4 states the following features can be adjusted and set Divide Point This allows you divide the sign into two s...

Page 17: ...ns unchanged and a dead zone i e no LEDS illuminate here is created Similarly when Section 2 is being set the 1 button will advance Section 2 into Section 1 causing the Section 1 divide position to re...

Page 18: ...peration 0 Whole sign on 1 Flash whole sign second on second off 2 Pulse whole sign 4 pulses in second on second off 3 Fade whole sign fade up in 2 seconds fade down in 2 seconds 4 Flash alternate Sec...

Page 19: ...the dead zone is visible If the display is still off then 1 Press the COLOUR 5 button again and press the 2 button to ensure that Section 1 is assigned a colour 2 Press the COLOUR 5 button again and p...

Page 20: ...Sign LD 40F1PHN 40cm PHONE Sign LD 40F1TRF 40cm TRAFFIC FLAG ON Sign LD 40F1ADB 40cm AD BREAK Sign LD 40F1REH 40cm REHEARSAL Sign LD 40F1DOR 40cm DOOR Sign LD 40F1OBT 40cm OBIT Sign LD 40F1NOE 40cm NO...

Page 21: ...d Side fitting instructions If you would like the sign to be viewable with the left hand side of the sign mounted onto the wall please use the Left Hand Side fitting instructions Fig 5 1 Sign Componen...

Page 22: ...p screws See Fig 5 5 Do not substitute any other screws in these positions and do not reuse the screws removed from these positions because they will not support the sign correctly 8 Please refer to t...

Page 23: ...on the left hand flush mount assembly by removing the self tapping screw with a No 1 pozi drive screwdriver 6 Remove the flush wall mount moulding from the end moulding by unscrewing the 4 screws visi...

Page 24: ...ETING IN PROGRESS Turns the sign off Turns the whole sign solid red when connected to 0V LD 40F1NOE NO ENTRY Turns the sign off Turns the whole sign solid red when connected to 0V LD 40F1OBT OBIT Turn...

Page 25: ...whole sign solid green when connected to 0V Turns the sign off LD 40F1NOE Turns the whole sign solid green when connected to 0V Turns the sign off LD 40F1OBT Turns the whole sign solid white when con...

Page 26: ...Notes...

Page 27: ...Notes...

Page 28: ...www sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...

Reviews: