23
connected via ethernet. If the unit fails to connect via DHCP, it will connect via a static
address instead. Please note that the DHCP connection attempts will abort after 45
seconds if unsuccessful. While connecting, the IP address, subnet mask and default
gateway will all read 0. 0. 0. 0. if read serially.
IP Address
- Displays the current IP address of the unit. If DHCP is enabled then this will
normally be the IP address supplied by the DHCP server.
Subnet Mask
- Displays the current subnet mask for the unit.
Default Gateway
- Displays the current default gateway for the unit.
MAC Address
- The unit’s MAC address. This cannot be changed.
Change Static Address
- This allows you to alter the static address stored in the unit. This
is the address that is used when DHCP is disabled or a DHCP server is not found. Selecting
this button allows you to enter your own IP, subnet and gateway addresses in the edit
boxes.
NB. The units are discovered using broadcast packets. If your PC has two network
cards, then there is a limitation in windows that requires the two addresses to be on
different subnet addresses.
Updating The Firmware
The RB-DSD8 firmware will at times be updated to add new features, or to correct any
possible issues that may arise.
Check for updates at: http://www.sonifex.co.uk/technical/software/
Firmware updates can be conducted through either Serial/Ethernet port. To update the
firmware, click on the button labelled “Update Firmware” and then select the downloaded
firmware file. Firmware files for the RB-DSD8 always have an “.ldr” extension. A progress bar
will appear in SCi, indicating how much of the file has been uploaded to the unit. When
the unit switches to update mode, the front panel display LEDs will all be extinguished. The
switch mode buttons are then used to display the status of the upload:
Uploading the Code:
The SLAVE button will begin to flash amber to confirm the unit is
receiving the new firmware to RAM.
Copying Code To Flash Memory:
The SLAVE button will be solid amber while the unit
checks the integrity of the file and copies the file from RAM to flash memory.
Successful Update:
The AUTO button will be solid green for two seconds and the unit will
automatically reset and begin running the new code.
Unsuccessful Update:
The MANUAL button will be solid red for two seconds and the unit
will return to running the last code used.
SCI FOR RB