91
Failover Switchers - RB-FS42 & RB-FS42DC 5
Home Page
Fig 5-9: The RB-FS42 Home Screen
Input Status
The current status of the 4 main input channels and each of
the 2 standby channels. Green indicates a valid signal and
red indicates an invalid signal.
Output Status
The current status of the 4 output channels. Green indicates
a valid signal, red indicates an invalid signal and grey
indicates that the channel is routing silence. If the channel
is routing a standby signal, the standby channel number will
appear inside the indicator.
Note:
The Status for standby 1 and 2 are labelled “I” and
“II” respectively. This is to allow clear indication of when a
specific channel is routing a standby signal.
Power Supply Status
The current status and an approximate voltage of each
power supply are shown here. Red indicates that the voltage
supplied is not within the acceptable range.