3
Front Panel Controls 2
The Front Panel consists of three areas:
- Status indicators on the far left.
- Channel controls and indicators in the centre.
- Monitoring outputs on the far right.
Status Indicators & Stereo Input 1
On the left hand side there are 4 status indicators, an unbalanced stereo
analogue audio input on a 3.5mm jack socket and a recessed reset button.
Indicators:
AC PSU
Indicates the status of the internal AC-DC power supply as follows:
Green
AC-DC generated voltage is within normal operating range
of +11V to +13V. This is the normal condition.
Amber
AC-DC generated voltage less than +11V or greater than
+13V. This indicates a warn condition.
Red
AC-DC generated voltage is less than +10V or greater than
+14V. This indicates a fault condition.
2. Front Panel Controls & Indicators
Fig 2-1: AVN-PXH12 Front Panel
L
oudspeaker
Status
Indicators
2 x Headphone
Outputs
Unbalanced
Stereo Input
Control Buttons, 3 for each
of the 12 Channels
Loudspeaker Volume
Control & Mute Button
Headphone
Volume Control
Reset
DC PSU
Indicates the status of the DC power input as follows:
Green
DC voltage is within normal operating range of +11V to
+13V. This is the normal condition.
Amber
DC voltage less than +11V or greater than +13V. This
indicates a warn condition.
Red
Not connected or DC voltage is less than +10V or
greater than +14V. This indicates a fault condition if a DC
power source is connected.
Fig 2-2: AVN-PXH12 Status
Indicators & Front Panel Controls