background image

LC-RL-4-W User Manua

l

Sonetonix

2

1.2 Override Input

An override input is provided to allow an external contact closure to momentarily override

the control system program and set all channels output to its override pre-set state.

1.3 Front panel

Four tactile switches on the front panel provide two functionalities. One, the Device’s S-

NET id can be programmed manually at any time, using the CH1 (1) and CH2 (2) keys. The other

functionality of these switches is to navigate through the channels manually along with channel

status indication LEDS.

1.4 Loads

Two pin detachable terminal blocks on the rear side for each channel to control the

controllable devices. Live IN (230VAC Mains @50hz) to be connected on Pin 1 and Live output

to be taken from Pin 2 and connect to Load Live.

1.5 S-NET

The LC-RL-4-W communicates with all Sonetonix products or third party units via S-NET.

A pair of S-NET terminal blocks, allow for easy

daisy-chaining of several DIN rail Series

automation control modules. 12VDC, S+, S- and Ground should be connected in each S-NET

terminal.

Summary of Contents for LC-RL-4-W

Page 1: ...User Manual LC RL 4 W Wall Mount 4 CH RELAY Controller Heavy Duty...

Page 2: ...f this publication may be copied or reproduced without prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accorda...

Page 3: ...e or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dan...

Page 4: ...ower Requirements 3 2 3 Connections 3 2 4 Controls and Indications 3 2 5 Mechanical specifications 4 2 5 1 Enclosure 4 2 5 2 Environmental 4 2 5 3 Dimensions and weight 4 3 APPLICATION AND WIRING DIAG...

Page 5: ...type 20A per channel 4 isolated normally open relays for power switching Used in non dimmable lighting control screen control Water Fountain motor control Automatic Gate Shutter motor control up to 1...

Page 6: ...nctionality of these switches is to navigate through the channels manually along with channel status indication LEDS 1 4 Loads Two pin detachable terminal blocks on the rear side for each channel to c...

Page 7: ...DC 2 3 Connections CHANNELS 1 4 4 2 pin 5 08 mm detachable terminal blocks with SPST relay switch circuit 20A per channel LV TRIGGERS G 1 4 1 5 pin 5 08mm detachable terminal block to provide low volt...

Page 8: ...al specifications 2 5 1 Enclosure Wall Mount dark Gray metal sheet enclosure 2 5 2 Environmental Operating Temperature 0 to 45 C 2 5 3 Dimensions and weight Parameter Value Unit Height 4 20 Inches Wid...

Page 9: ...LC RL 4 W User Manual Sonetonix 5 3 Application and wiring diagram...

Page 10: ...ing mode Step 3 The default S NET ID will be displayed in terms of WDT LED blinking sequence Step 4 Press the 2 switches on front panel to set the S NET ID number Step 5 After choosing a suitable ID p...

Page 11: ...e under Command Description Response Get Device Info ID F2 F5 ID Device Type Device model F5 Get New Device Info F0 F2 F5 ID Device Type Device model F5 Set New Device ID FE ID F3 new ID FD F5 ID ch1...

Page 12: ...2 channels in scene FE 01 F7 02 05 01 01 00 00 04 01 00 00 FD Recall scene 5 for device ID 01 FE 01 F8 05 FD Set multiple control command to ON load 1 and Off load 2 after 5 seconds ID 01 FE 01 F6 02...

Page 13: ...r removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty...

Reviews: