S-36 VLF
– USER MANUAL
28
7
Technical specifications
Power supply:
Mains voltage:
230 V ± 10% / 50/60 Hz
Current input:
10 A
(nominal)
/ 15 A
(peak)
Power input:
max. 3000 VA
Output voltage
VLF:
5
…36 kV
RMS
, similar sinusoidal
DC:
±0…52 kV DC
Maximum load (VLF)
0.1 Hz
0.05 Hz*
0.02 Hz*
(option)
6 kV
RMS
8.9 µF
11.5 µF
15.0 µF
18 kV
RMS
4.9 µF
8.1 µF
15.0 µF
26 kV
RMS
3.3 µF
4.5 µF
9.9 µF
36 kV
RMS
2.4 µF
4.1 µF
8.
1 µF
Output current (DC)
Overcurrent tripping:
±10 mA
Measuring ranges
Voltage:
-60
… 0 … +60 kV
Current:
±100 µA / 1 mA / 10 mA
Measuring error
Digital measurement
±1%
Analog meters
±2%
Discharge device
Max. discharge capacity:
12500 J according to relation
2
2
C
U
E
(i.e. C = 10
µF at U = 50 kV)
Operating temperature:
-
20°C … +45°C
Storage temperature:
-
25°C … +55°C
Weight
Operating device
17 kg
High-voltage device
48 kg