background image

 
 

 

Summary of Contents for MIC-2505

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...OPERATING MANUAL INSULATION RESISTANCE METER MIC 2505 SONEL SA ul Wokulskiego 11 58 100 widnica Version 1 01 17 02 2012...

Page 6: ...ersion 1 01 2 MIC 2505 meter is a modern easy in use and safe measuring device Please acquaint yourself with the present manual in order to avoid measuring errors and prevent possible problems related...

Page 7: ...ER SUPPLY 13 5 1 MONITORING OF THE POWER SUPPLY VOLTAGE 13 5 2 REPLACING RECHARGEABLE BATTERIES 13 5 3 CHARGING RECHARGEABLE BATTERIES 13 5 4 GENERAL PRINCIPLES REGARDING USING NIMH RECHARGEABLE BATTE...

Page 8: ...ipment in rooms with special conditions such as fire or explosion hazard It is unacceptable to operate the following a damaged meter which is completely or partially out of order a meter with damaged...

Page 9: ...ETUP button pressed Use and buttons to set the auto off time or cancel auto off function horizontal lines Press SEL button to enter the setting of no minal network frequency Use and buttons to set the...

Page 10: ...IC 2505 version 1 01 6 Use and to set Ab1 Ab2 parameters or PI DAR Press ENTER to display the measurement screen approving introduced changes or press ESC to go to the measurement scre en without vali...

Page 11: ...each other and the probe crocodile clips because such a contact may cause the flow of surface currents resulting in additional error in measu rement results Set the rotary switch of function selection...

Page 12: ...pressed a triangle with an exclamation mark will be displayed in dicating about automatic measurement now the buttons may be released In or der to interrupt the measurement press START or ESC View of...

Page 13: ...UISO voltage is stabilized Symbol LIMIT means operation with limited converter current If this condition persists for 20 se conds the measurement is interrupted If the timer reaches characteristic po...

Page 14: ...measurement when voltage previously reached the nominal value LED is lit in red two tone acoustic signal During the measurement AC voltage appeared or the ob ject cannot be discharged for 30 seconds...

Page 15: ...ors of the cable at taching to G terminal other conductors that do not take part in the measurement 3 3 Voltage measurement Set the rotary switch of function selection at U position Connect the meter...

Page 16: ...eter LED is lit in red two tone acoustic si gnal Voltage is higher than acceptable Immediately disconnect the test leads 4 Software updates Turn on the meter holding ENTER and SETUP buttons de pressed...

Page 17: ...ighter socket using an optional charger WARNING If the test leads are left in the terminals during replacement of the batteries the re is a risk of electric shock with a dangerous voltage To replace t...

Page 18: ...aximum capacity after being formatted 2 3 charge discharge cycles The most important factor which influ ences the lifetime of rechargeable batteries is the level of their discharge The deeper the disc...

Page 19: ...case of storage of the device the following recommendations must be observed Disconnect all the test leads from the meter Clean the meter and all its accessories thoroughly In the case the meter is to...

Page 20: ...um values of the measured resistance depending on the test voltage are presented in the table below For other voltages the range limits may be read from the chart below Voltage Test range 500V 500G 10...

Page 21: ...non standard condi tions and for metrological laboratories for the purpose of calibration Significant parameter Designation Additional uncertainty Position E1 0 Supply voltage E2 0 BAT is not lit Temp...

Page 22: ...cat IV 1000V WAPRZ005REBB5K 5kV lead 5m red with banana plugs WAPRZ005BUBB5K 5kV lead 5m blue terminated with ba nana plugs WAPRZLAD12SAM Cable for charging the accumulator package from the car cigare...

Page 23: ...urer of the device and provider of warranty and post warranty service SONEL S A ul Wokulskiego 11 58 100 widnica Poland tel 48 74 858 38 60 fax 64 74 858 38 09 E mail export sonel pl Web page www sone...

Page 24: ...OPERATING MANUAL MIC 2505 version 1 01 20...

Page 25: ......

Page 26: ......

Reviews: