background image

TELKAN 4 GSM 3G 

Telephonic Control Via GSM  Code:19.095

Manual of installation and use

  DESCRIPTION

  LED´s 

 SIM card

Input for external battery

External  input  for  a  sealed  lead  battery  of  12V  and  a 
capacity of 1.2 to 20Ah.

Input for temperature probes

r1, r2, r3, r4 

(Relays) 

External antenna connector

Connection for external antenna with magnetic base

 Contact closure alarms

When open / close contact for more than 5 seconds generates an alarm

a1, a2, a3 

(Alarms) 

t1, t2, t3 

(Probes)

b1 

(Battery)

PWR 

(Power supply)

GSM 

(Signal)

SIM 

(Card)

Input for transducer 4a20mA

Has the same procedure that input for probes. 

on          

Z

 in value alarm

off          

Z

 without value alarm

blinking 

Z

 Connection error

c1 

(Input 4a20mA)

Before  giving  the  power  to  the  control,  remove  the  SIM  card  PIN  and  insert  it  into  the  TELKAN

START UP

3

3

1

1

- Wiring type: H05VV-F or H05RR-F

-  Environment: Temperature 

Z

 

0°C to 45°C / Humidity 

Z

 

20% to 85% 

- Software classe A - Action type 1.B

- Free-voltage contact relay

- Independent dispositive

- According normative:  

EN 60730 / EN 301511 / EN 301489-1 / EN 301489-7

- Power supply:  230V~   +10% -15%  50/60Hz  max. 2VA

-  Measures: Rail-DIN box 6 modules (90x105x58 mm)

2     

2

- Minimum section for cable of: Relay 

Z

 

 2,5 mm  Power supply 

Z

 

1 mm  

- Contamination degree:  clean environment

TECHNICAL SPECIFICATIONS

Electrical drawing:

4

4

BAT

PWR GSM

SIM

BAT

PWR GSM

SIM

BAT

PWR GSM

SIM

5

5

IP20

If the installation was successful should light the LEDs: 

PWR

SIM

 and 

GSM

 Buttons ON / OFF

Connect /disconnect the relays manually without sending message.

Application 

(relays 

r2, r3

)

5A 250V~ SPST.

 Relays with free voltage-contact (operation as a 

switch)

T3

+

-

Battery

B1

5A

R3

C

NO

C

NO

NO

NO

R1

NC

C

L

230V~

N

SIM

ANTENNA

+

-

4a20mA

L

N

Contact Alarms

Temperature Probes PTC2000

C1

T1

T2

A1

A2

R2

NC

C

230V~

16A

16A

1 Input for external battery

: When detecting a change of power (battery passes network or vice versa) sends 

SMS warning of network failure and SMS of service restoration. (Battery not supplied, code: 7.190)

SIM:

 Works with prepaid card or contract of any company, it is recommended the prepaid for save money. Before 

purchasing the SIM, verify what company has the better coverage in the area. (SIM not included)

4 Relays (2x5A + 2x12A):

 : You can activate/deactivate manually or by SMS, activate /deactivate timed and query 

the status of the relay.

3 Inputs for T Probes

: Allows receive warnings of a temperature alarm, the relay can be linked to temperature 

alarm and view the history of temperatures for the last 4 hours via SMS. (Probes not supplied, code: 4.343)

1 Input for 4a20mA:

  Has the same procedure that input for probes. 

1 Alarms contact

: When open / close contact for more than 5 seconds will generate an alarm.

IP65 Box

: Box for surface mounting. (Box not supplied, code: 7.118)

Remote  control  via  GSM  that  works  by  sending  and  receiving  SMS  (configurable  in  2  languages,  Spanish  / 
English). Ability to operate powered 12V ideal photovoltaic installations.

Connection  for  temperature  probe  PTC2000  (-40°C  ...  +  140°C). 
When  the  probe  detects  that  the  temperature  has  crossed  the 
threshold defined by the user, the controller sends an SMS alarm 
only  to  phone  No  function  has  been  activated.  (F.  MEET,  can 
activate the desired relay).

Cardholder  to  insert  a  Mini-SIM  that  is  operational  and  any 
company. Does not work with Mini-SIM card or the phone number 
doubled.

 Do not insert or remove the SIM card with the Sondertel 

powered.

2 - Check with a mobile phone the SIM (which has no access PIN code, the credit,  

sending and receiving SMS).

1 - Install the control away from contactors, motors ... etc. It may be the case with 

some contactor with strong electromagnetic peaks need to install a relay between 
the output of 

TELKAN 

and the contactor coil.

3 - Insert SIM in 

TELKAN

.

4 - make the rest of connections.
5 - Connect the control to the power supply  230V~

A3

R4

on  

Z

 in alarm

off  

Z

 Without alarm

on  

Z

 relay connected

off  

Z

 realy disconnected

  

on          

Z

 in temperature alarm

off          

Z

 without temperature alarm

blinking 

Z

 Connection error

on  

Z

 power supply by battery

off  

Z

 power supply by 230V~

on  

Z

 powered supply

off  

Z

 without power supply

on          

Z

 wiht signal GSM

off          

Z

 without signal GSM

blinking 

Z

 sending dates or

                             SMS received

on          

Z

 inserted and operational

off          

Z

 without card SIM

blinking 

Z

 the card has PIN

      (take out of TELKAN & disabled the PIN)

Cod.:7955 INGVØ ENE19

OPERATING TEMPERATURE ALARM

30°C

31°C

29°C

Temperature

Device is 

out 

of alarm

Device is 

inside 

the alarm

First off set the temperature for alarm for example 30°C ± 1°C (differential of activation) may also indicate the time that has to remain above or below to consider that is in alarm. 
You can define two different values or the same for the delay time (Delay). Factory goes to 0 and alerts at the same time the temperature goes from temp alarm ± 1°C. 

Delays are very useful to discriminate when a temperature alarm of a product load in cold rooms where there are short peaks and temperature are controlled. 

5 min.

Actives  the  alarm  in  case  of  being  more  than  5  minutes  (time  delay)  above  31°C 
(temperature alarm + differential) and does not disable the alarm until it is below of 
29°C over 5 minutes (temperature alarm - differential)

0000 alarm t1 30     

delays 5 minutes for activation and deactivation

Temperature for alarm: 30°C  + fixed Dif.: ± 1°C

0000 delay t1 5

SMS

For the rest of general conditions visit our web.

- Apparatus modified without the consent of the manufacturer.

deleted or modified.

according to the instructions accompanying the appliance.

- Devices whose deterioration is the result of impact or liquid

Reserved the right to change without prior notice.

or gaseous emanations.

- Devices whose connection or use has not been executed

- Equipment whose serial number has been damaged,

We decline any responsibility for damaged equipment result
of poor handling. Not included in the warranty:

This device has 3 year warranty according to the date of manufacture, 

it is limited to replacement of faulty part. Transport not included.

CONDITIONS OF GUARANTEE

SONDER

delay for activation 5 and 10 minutes for deactivation 

0000 delay t1 5 10

Example:

Very important:

Device  designed  for  a  situation  of  pollution 
clean.

Control  device  for  DIN  rail  mounting  and 
connection via fixed pipeline.

When  installing  control  ensure  you  have  good 
coverage  away  from  contactors  and  other 
signals that may interfere.

This control is not a safety device, and can not be 
used  as  such,  it  is  the  installer  responsibility 
incorporate adequate protection to every type 
of installation (

HOMOLOGATED

Must comply with 2 factors: Tempe Time Set

IN CASE OF:

SMS received

- The 

TELKAN 

saves the last 5 phone numbers that have given a correct order and if they make a lost call, the TELKAN sends an SMS of state, but the SMS that an alarm has 

occurred only is sent to the numbers set in INFORM function. 

         • If the control is configured with the function PROMO in off, is deleted.

- If the SMS received by the 

TELKAN 

not start with numeric digits and comes from an unknown telephone is interpreted as a message from the phone company:

         • If the control is configured with the function PROMO in on, the SMS is forwarding to all phones set in Function Inofrm 

- Send an wrong SMS to the 

TELKAN 

from a phone that had 

previously made valid orders.

- The temperature exceeds the limit set by the user

Alarm: T1
T1: 33.5C
A1: off
B1: MAIN

ERROR: invalid language. 0-Castellano, 1-English.

- If a request to change languages includes an invalid number

T1: 26.8C
A1: off
B1: MAIN

- Message received periodically according to set time with 

the function 

Alive 

activated

pwrd +
on - relay on
off - relay off
inform on - receive alarm
test - status
pass xxxx - change password

Probe set for alarm
Reading probe alarm
Disconnected alarm contact
Main power supply

Temperature read by probe T1
Alarm 1 off
Main power supply

- Make a call to 

TELKAN 

from a phone that had previously 

made valid orders.

R1: on
R2: off
T1: 26.8C
T2: 35C
A1: off
B1: BATT (11.799V)

Password (set from factory to 0000) + followed by the command:
order - (meaning that order)

SMS 

Status query

:

State relays
Current temperature read by probes
Alarm status
battery connected (value of charge)

Warning! The volatge of 
the battery is very low.
BATT (9.112V)

-  Message  received  when  the  control  detects  that  the 

battery power is low.

Warning low battery with charge value

Sonder Regulación, S.A.

Avda. La Llana, 93 

08191 RUBÍ

(Barcelona) Spain

www.sonder.es

230V~ +10% -15%  50Hz   máx. 2VA

Power supply

Application 

(relays 

r1

,

 r2

)

12A 250V~ SPDT. 

Relays 

with free voltage-contact 

(operation as a switch)