Issue B3
11. For fitment instructions of the directional transducer endcap, see
Directional Transducer Endcap"
; for fitment instructions of the omni-directional transducer
endcap, see
Section 8.10.2 "Fitment of the Omni-Directional Transducer Endcap"
.
8.9 Removal and Fitment of a Directional Transducer Endcap
If the transponder is configured with a directional transducer endcap the removal and fitment
procedures will different to that of the omni-directional transducer.
8.9.1 Directional Transducer Endcap Removal
1. Ensure the transponder has been cleaned with clean fresh water and any marine growth
removed; see
2. Operate the pressure relief vent valve to release any internal pressure; see
"Operating the Pressure Relief Vent Valve"
3. Undo, remove and retain the six nuts, washers
and white nylon spacers
from the end of the
guard
protecting the transducer
; see
Figure 8–3 Removing the Protective Guard
Guard
Nylon Spacer
Transducer
Washers and Nuts
Rubber Bump Stop
4. Lift the end of the transponder housing a small amount to allow the protective guard
and bump
stop
to be removed from the clamp rings
; see
Section 8 – Maintenance
39