Section 8 – Firmware Update
18
Section 8 – Firmware Update
8.1 Introduction
The Lodestar firmware can be updated in the field by using the Lodestar PC utility software tool
(included with the Lodestar 500). Customers will be informed of any required firmware updates by
Sonardyne support.
The Lodestar will accept firmware updates on the CP port only.
To update the firmware using Lodestar PC Utility via a serial connection, follow the procedures in
Sections 8.2.1
and
8.2.2
.
8.2 Updating the Firmware
8.2.1
Pre-requisites
Before upgrading the firmware, ensure you have the following available:
•
The new firmware file (IMU.hex)
•
A serial connection to the Lodestar on the CP port.
•
A Lodestar PC Utility installation.
8.2.2
Update Procedure
1.
Connect the Lodestar CP port to the PC either directly via RS232 or through a Navigation
Sensor Hub (NSH).
Note
Wait two minutes after applying power to allow the Lodestar 500 to start up.
2.
Click
Start > Programs > Sonardyne > Lodestar > Lodestar
to open the Lodestar PC Utility.
3.
Click
Connect