5
3. When both connections at the speaker are complete,
use a wire tie to manage the extra slack and provide
strain relief to the connection.
4. Place the speaker over the completed wire
connections.
5. Repeat steps 2 through 5 at each speaker location.
Alternate between using the left channel wires
(white/green) and the right channel wires
(red/black). See the AMPLIFIER CONNECTIONS
SECTION for more detailed wiring diagrams.
Figure 8: Prepared Wires
AMPLIFIER CONNECTIONS
Once all speaker connections have been completed,
connect the 2-conductor or 4-conductor wire to your
amplifier. Take care to ensure that no excess copper
strands are exposed to prevent shorting or other
dangerous electrical hazards.
Connect an audio source to the amplifier. Power on the
amplifier and test the speakers.
CLASS 2 WIRING
8
ΩMIN
BRIDGE
1- RIGHT
1- LEFT
AC 100-120V ~ 60Hz
AC 220-240V ~ 50Hz
MADE IN CHINA
275
w
at
ts
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
IN
OUT
IN
OUT
1-L
1-R
2-L
2-R
T15AL / 250VAC
CAUTION
REPLACE FUSE ONLY
WITH
SAME TYPE AND RATING
ATTENTION
REMPLACER UNIQUEMENT AVEC
LE MEME TYPE ET CALIBRE DU
FUSIBLE
S/N
SONANCE DSP2-750
IN
OUT
3-30 VOLTS
AC or DC
VOLTAGE TRIGGER
IR
CONTROL
IR
STATUS
IN
OUT
TCP/IP
DHCP ON - DEFAULT
Figure 9: 2-Conductor Trunk
Figure 10: 4-Conductor Trunk
+
+
-
-
To Ne
xt Speak
er
CLASS 2 WIRING
8
ΩMIN
BRIDGE
1- RIGHT
1- LEFT
AC 100-120V ~ 60Hz
AC 220-240V ~ 50Hz
MADE IN CHINA
275
w
at
ts
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
IN
OUT
IN
OUT
1-L
1-R
2-L
2-R
T15AL / 250VAC
CAUTION
REPLACE FUSE ONLY
WITH
SAME TYPE AND RATING
ATTENTION
REMPLACER UNIQUEMENT AVEC
LE MEME TYPE ET CALIBRE DU
FUSIBLE
S/N
SONANCE DSP2-750
IN
OUT
3-30 VOLTS
AC or DC
VOLTAGE TRIGGER
IR
CONTROL
IR
STATUS
IN
OUT
TCP/IP
DHCP ON - DEFAULT
+
+
-
-
To Ne
xt L
eft Speak
er
+
+
-
-
To Ne
xt Right Speak
er
Green
White
Red
Black
Figure 7: Wire Jacket Removed
White/Green = Left
Red/Black = Right