FEATURES
The dehumidifier can be used to reduce the humidity of damp premises thus reducing the
chance of mold or mildew from appearing. The unit draws in humid air then uses its built-in
compressor and evaporator to extract moisture from the air. The moisture extracted from
the air is collected in the unit’s water tank or can be continuously drained away using the
drain pipe. Due to the operating principle, it is not suitable for increasing humidity of the
room.
2
• recommended room size: 20 - 30 m • 4 operation modes (AUTO, QUIET, DRY, FAN) •
separately switchable ionization • memory for last settings • adjustable desired humidity
(35% - 80% RH) • 1 - 24 hour, shutdown timing, adjustable per hour • 3,0 l water tank,
indication light for full tank • included drain pipe (1 m) to be used optionally
STRUCTURE (FIGURE 1.)
1. carrying handle • 2. control panel • 3. air deflector / air outlet • 4. removable washable filter
/ air inlet • 5. removable water tank • 6. castors • 7. power cable • 8. drain pipe
INSTALLATION
- Before installation, carefully remove the packaging material taking care not to damage the
appliance and power cable. Do not use the product if it is damaged in any way!
- Before switching it on for the first time, keep standing it on its castors for one hour!
- If you would like to use the drain pipe, connect it according to
Figure 3.
!
- Plug the unit’s completely unwind power cable into a standard grounded wall outlet!
- With this step, the unit is ready for operation.
USE
Before switching on the unit, air deflector (3) on its top has to be opened by hand up to
maximum 60°. It can not be opened to vertical position, do not overtighten the air deflector!
Appliance can be switched on with the
POWER
button. Display will show the current
relative humidity of the room. POWER and AUTO indicator lights are lit, the fan starts
spinning. Unit can be switched off with the POWER button as well. After pushing the button,
the compressor will stop working, the fan will spin for more 15 seconds, and stops after.
By pushing the
ION
button, the built-in ionizer can be switched on, which will enrich the
blown out air with negative ions. Switched on ionizer will be indicated by ION light.
You can choose between varied operation modes with
MODE
button.
AUTO:
In this mode, the appliance wants to reach factory-set 55% RH level, desired
humidity level can not be modified.
RH ≥ 70%: increased fan speed, powerful dehumidification
RH 55 – 70 %: normal dehumidification, lower fan speed
RH <55%: fan works only, the compressor doesn’t
QUIET:
The unit works with low fan speed, ideal for operation at night. In this mode, desired
humidity can be set from 35% to 80%, with 5% increments. With ▲ and ▼ buttons you can
increase or decrease the desired humidity, which will be flashing on the display. After setting
has finished, the display will show current humidity again.
DRY:
Appliance will work with maximum speed level, ensuring the maximum dehumidifying
capacity. Humidity can be adjusted as written in the previous paragraph.
FAN:
The fan works only on low speed level.
Shut down timing for 1- 24 hours, with one hour increments can be set by repeated pressing
of
TIMER
button. Set value will be flashing on display. “00” value shows when timing is
switched off.
Operation mode of the unit and the set humidity will control switching on and off the
compressor. When the compressor is working, warm air flows out through the air outlet,
which is natural and not malfunction. Switching the compressor on or off will be
accompanied by a slight vibration, which will be stopped during continuous operation.
WATER TANK
Appliance will stop operation, if the water tank is full, or it is not at its place. Red –FULL –
indication light will be on and the unit will beep for 15 seconds.
Emptying the water tank
- Power off the unit by unplugging it from the electric outlet prior to emptying the water tank!
- Hold the water tank (5) on both sides and pull it out from the unit!
- Slowly pour out the collected water then carefully replace the water tank.
Continuous drainage
If you plan to use the unit continuously for dehumidifying, you can use the accessory drain
pipe (8). If you use a drainage pipe, the water tank will also need to be in place.
- Power off the unit by unplugging it from the electric outlet prior to connecting the drain pipe!
- Remove the water tank and empty if necessary.
- Connect the included pipe according to
Figure 3.
- Replace the water tank to the unit.
- Please ensure that the drain pipe does not become clogged, pinched or frozen with an
ice-plug.
CLEANING
In order to ensure optimum functioning, the unit may require cleaning at least once a month,
depending on the manner of use and degree of contamination.
1. Switch off and power off the unit by unplugging it from the electric outlet before cleaning!
2. Clean the air in- (4) and out- (3) lets with vacuum cleaner! You can remove the filter at the
air inlet opening, and wash it with clean water. Place only dry filter back into the appliance.
3. Use a slightly moistened cloth to clean the unit’s outer surface. Do not use any aggressive
cleaners. Avoid getting water inside of and on the electric components of the appliance!
TROUBLE SHOOTING
SPECIFICATIONS
dehumidifying capacity
: . . . . . . . . 18 l / 24 h (30°C, RH: 80%)
. . . . . . . . . . . . . . . . . . . . . . . . . 10 l / 24 h (27°C, RH: 60%)
voltage
: . . . . . . . . . . . . . . . . . . . AC 220-240 V ~
frequency
: . . . . . . . . . . . . . . . . . 50 Hz
rated power
: . . . . . . . . . . . . . . . . 300 W
rated current
: . . . . . . . . . . . . . . . 1,4 A
max. power
: . . . . . . . . . . . . . . . . 400 W
max. current
:. . . . . . . . . . . . . . . . 1,9 A
max. suction pressure
:. . . . . . . . . 0,6 MPa
max. discharge pressure
:. . . . . . . 1,6 MPa
It contains fluorinated greenhouse gases covered by the Kyoto Protocol. Hermetically
sealed.
coolant
: . . . . . . . . . . . . . . . . . . . R134a / 0,1 kg
. . . . . . . . . . . . . . . . . . . . . . . . .
EQV CO :
0,143 t
2
. . . . . . . . . . . . . . . . . . . . . . . . .
GWP R134a:
1430
operating temperature
: . . . . . . . . 5 – 32 °C
noise level
: . . . . . . . . . . . . . . . . . 45 dB(A)
water tank size
: . . . . . . . . . . . . . . 3,0 l
length of drain pipe
: . . . . . . . . . . . 1 m
3
air delivery rate
:. . . . . . . . . . . . . . 160 m /h
IP protection
: . . . . . . . . . . . . . . . IP20:
Not protected from ingress of water
!
length of power cable
: . . . . . . . . . 1,6 m
dimensions
: . . . . . . . . . . . . . . . . 320 x 560 x 220 mm
net weight
: . . . . . . . . . . . . . . . . . 14 kg
Malfunction
The fan is working
but the compressor doesn’t
.
Appliance stops working
.
Wind noise is very strong
.
The unit doesn’t dehumidify
properly
.
Solution
Check the operation mode and the adjusted
humidity
!
Empty the water tank
!
Put back the water tank to its place properly
!
Timer may switched off the appliance
.
Open up the air deflector
!
It is not a malfunction in case of DRY or AUTO
operation mode
.
Clean the air filter
.
Do not cover the air in- and outlets
.
• When not planning to use the unit for an extended period of time, switch it off then remove the power
plug from the outlet. Store the appliance in a cool, dry place!
• Hold the plug, not the power cable when you pull it out from the electric outlet!
• The unit is intended for household use only. No industrial use is permitted!
Caution: Risk of electric shock!
Do not attempt to disassemble
or
modify the unit or its
accessories. In case any part is damaged, immediately power off the unit and seek the assistance of
a specialist.
I
n the event that the power cable should become damaged, it should only be replaced by the
manufacturer, its service facility or similarly qualified personnel.