KKEW9LC05-A/0-20160901
Panel Indication
1
2
3
4
5
6
U
A
P
F
E
EP
EN
E
EP
EN
page 2 /15
≥300KΩ
AC 0.025 ~ 5A
<0.4VA (each phase)
<20m
Ω
AC/DC 100 ~ 240V (85 ~ 265V)
≤
7VA
-25 ~ 70
℃
96W×96H×104.6L(mm)
0.6kg
Voltage impedance
Voltage Accuracy
Current Range
Current Overload
RMS measurement , Accuracy : 0.5
Continuous: 1.2 times Instantaneous: 10 times/10S
Current Consumption
Current impedance
RMS measurement , Accuracy : 0.5
Current Accuracy
Frequency
30-500Hz , Accuracy: 0.1Hz
Power
Active power/Reactive power/Apparent power, accuracy: 0.5
Energy
Active power accuracy 0.5 / Reactive power accuracy 1.
Display
LCD Display (can select blue backlight, white backlight as default)
Power Supply
Power Supply Consumption
RS-485 Modbus-RTU Protocol
Output Digit Interface
Pulse Output
2 energy pulse output (optical coupler relay) Normal Pulse constant: 9000imp/kwh
On/Off Input
Alarm Output
Analog Output
Working Environment
Storage Environment
Isolation & puncture
Insulation
Dimension
Weight
4 On/Off input (connection without voltage or current signal)
2 On/Off output, 250VAC/3A or 30V DC/5A
1 transformed analog output, 4-20mA DC Load<500Ω
Temperature: -10 ~ 50
℃
, Humidity: <85% RH; no corrosive gas; altitude
≤ 2500m
Input signal and power 1600V AC , Input and output 1600VAC , power and transformed analog output, RS485
connection , DI connection , Pulse output connection≥DC 2000V
Input/output/power supply to Meter cover >5MΩ
Symbol
Meaning
voltage
current
power
Frequency
No.
symbol
Name
Function
Set Key
Check measuring value and working status indication:
1. Under measuring status , press / key to shift display of 3 phase voltage, 3 phase linear voltage, 3 phase current, total power, frequency, etc.
2. Press key / to shift display of Kwh and KvarH. (When second harmonic enable, use ESC to shift display of energy.)
3. Under alarm mode , DO1 and DO2 is used as alarm output status indication. Under ON/OFF remote control mode , DO1 and DO2 is used as
ON/OFF output status indication.
4. S1, S2, S3, S4 indicate switch signal remote control input status.
5. Alarm flash means alarm output, COM flash means communicating, RUN move means the meter is under measuring status.
6. E (kwh) means total active energy, E (kvarh) means total reactive energy.
Forward kvarh
Forward kwh
Inverse kwh
Total kwh
Total kvarh
Inverse kvarh
Left Key
Right Key
Decrease Key
Increase Key
Return Key
Press this key more than 3 seconds to enter the menu
Confirm the set value
In menu operation, it can shift menu
Change to display left page
In menu operation, it can shift menu
Change to display right page
In menu operation, it is used to enter data setting
Decrease value
In menu operation, it is used to enter data setting
Increase value
In menu operation, it is used to return to previous menu
2
3
1
4
5
6
v
v
v
a
b
c
M Wh
Intelligent Meter
SET
ESC
SET
ESC