background image

KKEL8E01-2

AC/DC 100

240V  50Hz/60Hz  DC 24V(

Need to be ordered 

)

0.001-9999
±0.5%F.S ±2digit((For AC the frequency should be under 100Hz

4

20mA 

AC 250V/3A or DC 30V/5A

96W*48H*100L

2 times/S

≥100MΩ/500V DC

3.Panel Indication

AL1:Alarm1# indicating light
AL2:Alarm2# indicating lignt

Parameter value/Input code displaying

1

.

Code Illustration

EL801-R2V600

IN1

0

10V

IN2

0

100V

IN3

0

600V

IN1

0

10V

IN2

0

100V

IN3

0

600V

IN1

0

10V

IN2

0

100V

IN3

0

600V

IN1

AC 0

5A  IN2:DC 0

75mV(meter displays 0

5A)

IN1

AC 0

5A  IN2:DC 0

75mV(meter displays 0

5A)

IN1

AC 0

5A  IN2:DC 0

75mV(meter displays 0

5A)   

IN1

0

10mA

0

100mA

IN2

0

1000mA

IN1

0

10mA

0

100mA

IN2

0

1000mA

IN1

0

10mA

0

100mA

IN2

0

1000mA

NO
4-20mA
4-20mA
NO
4-20mA
4-20mA
NO
4-20mA
4-20mA

NO
NO
RS485
NO
NO
RS485
NO
NO
RS485

IN3:600V

IN1:5A

IN2:1000mA

V

Voltage measuring indicating light

A

mA)

Current measuring indicating light

Code

Input channel and Range

Alarm

Analog output Communication

2 alarm

Default channel and range

2 alarm
2 alarm
2 alarm

2 alarm
2 alarm
2 alarm
2 alarm
2 alarm

When you use the meter, please pay attention that input channel should correspond to range, otherwise, the meter will be malfunction.

Input signal < 1.2 times of range.     

When measuring AC, aviliable for 0 

200Hz. When the frequency beyond 100Hz ,the accuracy is ±0.5%FS

2.Technical Specification

Power Supply
Display range
Accuracy

Analog output
Communication

Relay capacity

Dielectric Strength

Insulation Impedance

Ambient Temperature 

and humidity

Sampling rate

Dimension(mm)

float decimal point display

load capacity≤600Ω, accuracy:±0.5%F.S

Standard RS485 interface, Modbus RTU 

AC 1800V/1 min,0.5mA
DC 600V/1 min,0.5mA 

Temperature

0-50 

humidity

:≤

85%RH

Displaying measuring value/parameter code

SET:Parameter select/confirm key

Down key

Up key

Shift key

4.Operations

The second row LED is defaulted to display range and input channel alternately after power on, press “    ” only display range,

    press this key again the LED returns to default display status.

Press“SET”key>3S in the measuring status, the meter shows the parameter menu.

   /   

When modifying setting value, press “            ” to change value; press      to shift decimal point, after modifying completed, press 

    “SET” to  confirm and it shows the next menu. After setting completed, press “SET” >3S to exit menu. If you don’t operate it for a long 

    time, it will exit menu automatically.

Range

Version

 A:AC/DC Current   V: AC/DC Voltage

Blank: No RS485    8: With RS485

  1: One alarm    2: 2 alarms

Blank: No alarm   R: Relay alarm 

EL801 Series Voltage&Ampere Meter

Blank: No analog output    I

4~20mA analog output

EL801 

-

B

EL801-IR2V600

EL801-IR28V600

EL801-R2A1000
EL801-IR2A1000
EL801-IR28A1000

EL801-R2A1

EL801-IR2A1

EL801-IR28A1

Reviews: