KKEL8E01-2
AC/DC 100
~
240V 50Hz/60Hz DC 24V(
Need to be ordered
)
0.001-9999
±0.5%F.S ±2digit((For AC the frequency should be under 100Hz
)
4
~
20mA
AC 250V/3A or DC 30V/5A
96W*48H*100L
2 times/S
≥100MΩ/500V DC
3.Panel Indication
AL1:Alarm1# indicating light
AL2:Alarm2# indicating lignt
Parameter value/Input code displaying
△
1
.
Code Illustration
EL801-R2V600
IN1
:
0
~
10V
;
IN2
:
0
~
100V
;
IN3
:
0
~
600V
IN1
:
0
~
10V
;
IN2
:
0
~
100V
;
IN3
:
0
~
600V
IN1
:
0
~
10V
;
IN2
:
0
~
100V
;
IN3
:
0
~
600V
IN1
:
AC 0
~
5A IN2:DC 0
~
75mV(meter displays 0
~
5A)
IN1
:
AC 0
~
5A IN2:DC 0
~
75mV(meter displays 0
~
5A)
IN1
:
AC 0
~
5A IN2:DC 0
~
75mV(meter displays 0
~
5A)
IN1
:
0
~
10mA
、
0
~
100mA
;
IN2
:
0
~
1000mA
IN1
:
0
~
10mA
、
0
~
100mA
;
IN2
:
0
~
1000mA
IN1
:
0
~
10mA
、
0
~
100mA
;
IN2
:
0
~
1000mA
NO
4-20mA
4-20mA
NO
4-20mA
4-20mA
NO
4-20mA
4-20mA
NO
NO
RS485
NO
NO
RS485
NO
NO
RS485
IN3:600V
IN1:5A
IN2:1000mA
V
:
Voltage measuring indicating light
A
(
mA)
:
Current measuring indicating light
Code
Input channel and Range
Alarm
Analog output Communication
2 alarm
Default channel and range
2 alarm
2 alarm
2 alarm
2 alarm
2 alarm
2 alarm
2 alarm
2 alarm
When you use the meter, please pay attention that input channel should correspond to range, otherwise, the meter will be malfunction.
①
Input signal < 1.2 times of range.
②
When measuring AC, aviliable for 0
③
~
200Hz. When the frequency beyond 100Hz ,the accuracy is ±0.5%FS
2.Technical Specification
Power Supply
Display range
Accuracy
Analog output
Communication
Relay capacity
Dielectric Strength
Insulation Impedance
Ambient Temperature
and humidity
Sampling rate
Dimension(mm)
float decimal point display
load capacity≤600Ω, accuracy:±0.5%F.S
Standard RS485 interface, Modbus RTU
AC 1800V/1 min,0.5mA
DC 600V/1 min,0.5mA
Temperature
:
℃
0-50
humidity
:≤
85%RH
Displaying measuring value/parameter code
SET:Parameter select/confirm key
Down key
Up key
Shift key
4.Operations
①
The second row LED is defaulted to display range and input channel alternately after power on, press “ ” only display range,
press this key again the LED returns to default display status.
②
Press“SET”key>3S in the measuring status, the meter shows the parameter menu.
/
△
△
△
③
When modifying setting value, press “ ” to change value; press to shift decimal point, after modifying completed, press
“SET” to confirm and it shows the next menu. After setting completed, press “SET” >3S to exit menu. If you don’t operate it for a long
time, it will exit menu automatically.
△
Range
Version
A:AC/DC Current V: AC/DC Voltage
Blank: No RS485 8: With RS485
1: One alarm 2: 2 alarms
Blank: No alarm R: Relay alarm
EL801 Series Voltage&Ampere Meter
Blank: No analog output I
:
4~20mA analog output
EL801
-
B
EL801-IR2V600
EL801-IR28V600
EL801-R2A1000
EL801-IR2A1000
EL801-IR28A1000
EL801-R2A1
EL801-IR2A1
EL801-IR28A1