Copyright © 2016 Somfy SAS. All rights
reserved.
EN
6
Electrical door-opener controlled by a "normally closed" contact
The keypad is configured to work in normal open mode (NO) using its 3 relay outputs.
If one of the relays is used in normally closed mode (NC), it is necessary to position the
jumper that matches this relay in the "NC" position:
E.g.:
SW2 SW1 NC3 NO3
MOV
C3 NC2 NO2 C2 NC1 NO1
NO1
NO2
NO3
NC1
NC2
NC3
C1 _ +
Relay 1
NO
Relay 2
NC
Relay 3
NO
SW1 and SW2 terminals
It is possible to wire a push-button between the SW1 terminal and the "-" terminal in order
to be able to activate relay 1 with the same parameters as the keypad.
It is possible to wire a push-button between the SW2 terminal and the "-" terminal in order
to be able to activate relay 2 with the same parameters as the keypad.
3 CONFIGURING THE KEYPAD
To access parameter setting, the master code needs to be entered twice.
The default master code is: 11111111