Sonesse 40 RS485
EN
Copyright
©
2021 SOMFY ACTIVITES SA. All rights reserved.
5
2.2.Wiring
2.2.1.Power wiring
PRECAUTION
• Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
• Secure cables to prevent any contact with moving parts.
• The drive cable cannot be removed. If it is damaged, return the drive to the After-Sales department.
• Leave the drive power supply cable accessible: it must be easily replaceable.
• Connection must be done in a junction box.
1]
Switch off the power supply.
2]
Connect the drive according to the information in the table below:
Neutral (N)
Live (L)
120 V
〜
50 Hz
White
Black
220 V
〜
60 Hz
Blue
Brown
230 V
〜
50 Hz
Blue
Brown
OFF
N
L
2.2.2.Data wiring
CAUTION
•
There is a RJ45 female to female coupler provided with the drive to add easily an
extension cable.
•
Make sure the data cable is not pinched or damaged during the installation of the
drive/tube onto the end bracket.
Connect the data cable to the drive according to the information in the tables below.
1: + RS485
5: Not connected**
2: - RS485
6: Not connected**
3: Not connected**
7: Not connected**
4: Power out *
8: GND
5
6
7
8
4
3
2
1
* The LSU Power Out characteristics comply with the following voltage and current characteristics: 8 V min – 50 mA max.
** If connected, the drive can be damaged.
NOTICE
The wiring guide is available for download at https://www.somfy.com/projects/downloads
Summary of Contents for Sonesse 40 RS485
Page 50: ...PT Sonesse 40 RS485 50 Copyright 2021 SOMFY ACTIVITES SA All rights reserved...
Page 58: ...DA Sonesse 40 RS485 58 Copyright 2021 SOMFY ACTIVITES SA All rights reserved...
Page 103: ...Sonesse 40 RS485 Copyright 2021 SOMFY ACTIVITES SA All rights reserved...
Page 104: ...Sonesse 40 RS485 Copyright 2021 SOMFY ACTIVITES SA All rights reserved...