22
Parametering your SGS/AXOVIA
2
Parametering your SGS/AXOVIA
2
E
n
g
li
s
h
ON/OFF
AUTO
PROG
ON/OFF
AUTO
PROG
l
Memorising the remote controls in total opening only :
Choose key of remote control which you wish to use to order your gate.
Place remote control against the target engraved on the hood:
l
Change of operating mode of the already memorized remote controls:
To switch remote control from
"opening total"
mode to
"opening pedestrian or total"
memorize remote control as mentioned above
"memorizing of the remote controls in opening
pedestrian or total"
. Last memorizing erases the preceding memorized mode. To switch
remote control from
"opening pedestrian or total"
mode to
"opening total"
mode, memorize
remote control as mentioned above
"memorizing of the remote controls in total opening"
.
Last memorizing erases the preceding memorized mode.
Maintain button to be memorized
pressed until the PROG light blinks slowly
(the DANGER
light lights up during
this operation)
1
Release button : it is memorized.
2
l
Memorizing remote controls in pedestrian or total opening:
Choose key of remote control which you wish to use to order your gate.
Place remote control against the target engraved on the hood:
Maintain button to be memorized
pressed until the PROG light blinks slowly
(the DANGER
light lights up during
this operation)
1
Release button
2
Again press (before 10 seconds) on key to memorize until PROG light blinks slowly (the
light DANGER
lights during this operation).
3
Release button : it is memorized.
4
At the end of the memorization cycle, only the PROG and ON/OFF lights are lit,
the electronics waiting for memorization of leaf displacement
At the end of these 4 steps, the PROG light turns off, indicating the end of the gate
displacement memorization procedure.
This cycle must be complete (2 complete, uninterrupted openings/closings). If it is
interrupted, the process is simply postponed and will be taken up again at the next
controlled opening.
• Make a long press on remote control
key.
> After a few seconds, the gate
opens at low speed.
* If the gate does not open correctly,
check the wiring of motors
1
• Once the gate is opened, push again a
new long press same remote control
key
> The gate closes, one leaf after the
other.
2
• Press once more on same remote
control key.
> The gate opens, still at slow speed.
3
• Press a last time.
> Both leaves close almost
simultaneously.
4
STOP
STOP
STOP
STOP
o
Memorisation of leaf displacement :
The Somfy electronics automatically memorizes :
• The force of the cylinders necessary for gate control in normal operation. This
memorization then makes it possible to detect any abnormal force on the motorization.
• The angles necessary for complete opening and closing of the gate leaves with
locating the stops. This memorization then makes it possible to slow down before
reaching on the stops.
In order to start up the memorization process with the LEAF CLOSED, stand at a normal
distance from the gate and respect the following steps :