SOMFY SYSTEMS, INC. reserves the
right to update, change or modify
these instructions without prior notice.
REF. NO: 940125A
COPYRIGHT C SOMFY SYSTEMS, INC.
2/03
SOMFY SYSTEMS, INC.
47 Commerce Drive
Cranbury, NJ 08512
SOMFY CANADA
6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2
SOMFY MEXICO S.A. De C.V.
Calle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex C.P. 53370
5) Back to the factory configuration (to
the OREA RTS motor memory using a previously recorded transmitter)
**A.
Perform a power cut in the following sequence:
1. Power-off - 2 sec. minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on
The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been recorded.
The motor is in PROGRAMMING STAT for 2 minutes.
reset
E
B.
RESTORING FACTORY MODE
Press and
the programming button for more than 7 seconds
of the NEW RTS transmitter. The end-product will jog briefly UP/DOWN
twice. Once after 1 second and again after 7 seconds. This indicates the
OREA RTS motor has been completely cleared.
HOLD
>5 sec.
PREVIOUSLY RECORDED TRANSMITTER
5 seconds
!
WARNING:
This type of power cut affects all
the OREA RTS motors on the same power line. To
avoid resetting of non-concerned motors, press briefly
any button of their assigned transmitter. (UP, STOP, or
DOWN) The non-concerned motors will return to
USER MODE.
**RESETTING MOTORS BACK TO USER MODE
NOTE: A double power cut cannot be achieved if the motor is still in
FACTORY or INSTALLER mode. First program a transmitter into
the memory of the motor.