background image

The end-product jogs briefly UP/DOWN
indicating that the LT RTS CMO motor is in
PROGRAMMING STATE.

The end-product jogs briefly UP/DOWN

If it is a new sensor:
If the sensor was previously recorded:

it will be recorded in the motor.

it will be deleted.

The end-product jogs briefly UP/DOWN

The memory of the receiver is cleared (all the previous
sensors are erased) and the new sensor is recorded.

Press for more than 2 seconds on the
programming button of an RTS transmitter/
channel which is already recorded in the motor.

Press BRIEFLY on the programming button
of the SOLIRIS RTS

.

sensor

Press for more than 7 SECONDS
on the programming button of the
new SOLIRIS RTS

.

sensor

4) Add or Delete an EOLIS or SOLIRIS Sensor RTS in the memory of LT RTS CMO motor

a) Enter the "PROGRAMMING STATE"

b) To record or delete a sensor

c) To Erase all the sensors and record a new one

LT RTS CMO motors will memorize up to 3 RTS Sensors

-

+

-

+

-

+

-

+

>2 Seconds

>7 Seconds

5) Resetting the motor's memory and recording a new

transmitter when the only transmitter is lost.

A.

**

Perform a power cut in the following sequence:

1. Power-off - 2 sec. Minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on

The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been recorded.
The motor is in INSTALLER MODE for 2 minutes.

WARNING:

This type of power cut affects all

the LT RTS CMO motors on the same power line.
To avoid resetting of non-concerned
motors, press briefly any button of their assigned
transmitter/channel. (UP, STOP, or DOWN)
The non-concerned motors will exit INSTALLER
MODE and return to USER MODE.

**RESETTING MOTORS BACK TO USER MODE

B.

NOTE:

Press more than 5 seconds on the programming button of the

NEW RTS transmitter. The end-product jogs briefly UP/DOWN
indicating that the transmitter has erased the previous

and recorded the new one.

transmitter

A double power cut cannot be achieved if the motor

is still in FACTORY or INSTALLER Mode. First program a
transmitter into the memory of the motor.

>5 sec.

NEW TRANSMITTER

5 seconds

!

Transmitter

previously

recorded

!

Summary of Contents for LT RTS CMO

Page 1: ... an awning it will open or extend the awning If the UP button extends the awning the wind sensor will also extend the awning during windy conditions THIS IS DANGEROUS Damage and injury could occur Do not proceed until proper operation of the transmitter is verified 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total of 5 channels ...

Page 2: ... POWER ON FOR FIRST TIME 1 Two positions have to be set the UP and DOWN limits This is achieved with the mechanical CMO limit switch unit Provide power to the motor Notice the motor will not respond to any transmitter until a transmitter is assigned to communicate with the motors receiver A Remove the protective cap covering the limit setting buttons on the motor head replace when finished B Depre...

Page 3: ...USLY UP DOWN pressed and held LT RTS CMO LT RTS CMO refer to the Warning note in Section LT RTS CMO LT RTS CMO Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor The motor is now in USER MODE Press the programming button on the RTS transmitter User Mode This mode is for operating the motor by the end user Two intermediate postions...

Page 4: ...indicating that the LT RTS CMO motor has memorized the second intermediate position IP2 2 Record the INTERMEDIATE POSITION IP2 referenced from the DOWN LIMIT of the end product REACH THE INTERMEDIATE POSITIONS DELETE AN INTERMEDIATE POSITION The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor is in a programming state The end product jogs briefly UP DOWN indicating that the t...

Page 5: ...Resetting the motor s memory and recording a new transmitter when the only transmitter is lost A Perform a power cut in the following sequence 1 Power off 2 sec Minimum 2 Power on 5 to 15 seconds 3 Power off 2 sec minimum 4 Power on The end product moves for 5 seconds in one direction to indicate that the double power cut has been recorded The motor is in INSTALLER MODE for 2 minutes WARNING This ...

Page 6: ...ODE and return to USER MODE RESETTING MOTORS BACK TO USER MODE B Press more than 5 seconds on the programming button of the PREVIOUSLY recorded RTS transmitter channel The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor has been completely cleared NOTE A double power cut cannot be achieved if the motor is still in FACTORY or INSTALLER Mode First program a transmitter into the...

Reviews: