background image

Power Supply

Description

Transmitters

Pictured below are all compatible controls

1

2

Motor's memory capacity with Telis, Decora RTS, Telis Soliris: maximum of 12 transmitters
plus an additional 3 RTS sensors.

A.

All motor feedback (previously audible "beeping") is now replaced by a visual jog. A jog is a short Up & Down movement of the motor

(0.5 second turn of the motor in each direction).

For initial programming provide power only to the motor being programmed.

B.

C. The LT RTS CMO motor in Factory Mode will not respond to any transmitter (as it did previously with RTS Motors) until a transmitter is

assigned to communicate with the motor's receiver. To assign a transmitter press its UP & DOWN buttons simultaneously until the motor jogs.

D. Before pressing the programming button on the transmitter, verify the motor directions (if DOWN on the transmitter corresponds to DOWN on

the end-product) and set the end limits of the motor. Refer to section 4.3 of this instruction.

E. The motor is packaged in "FACTORY MODE", and will remain in this mode until the programming button on the transmitter is pressed, thus

putting it into "USER MODE". ROTATION DIRECTION CAN ONLY BE MODIFIED IN "FACTORY MODE".

F. A double power cut cannot be achieved if the motor is still in FACTORY or INSTALLER Mode. First program a transmitter into the memory

of the motor.

G.

WARNING:

For the EOLIS/SOLIRIS RTS SENSOR to function properly, the transmitter which is memorized into the motor's receiver must be

configured correctly. The DOWN button MUST correspond to DOWN on the end-product. In the case of an awning, it will open or extend the awning.
If the UP button extends the awning, the wind sensor will also extend the awning during windy conditions. THIS IS DANGEROUS! Damage and injury
could occur. Do not proceed until proper operation of the transmitter is verified.

120 VAC / 60 Hz

The Master Channel on a 4 channel transmitter can be used as an additional individual
channel for a total of 5 channels, without the option of master control of all motors
Range: Up to 65 feet from the motor

TELIS 1 RTS

TRANSMITTER

DECORA RTS 1

SWITCH

TELIS 4 RTS

TRANSMITTER

TELIS SOLIRIS RTS

TRANSMITTER

DECORA RTS 4

SWITCH

SOLIRIS SENSOR RTS

TELIS 1 RTS

1 CHANNEL

UP

STOP

DOWN

CHANNEL

INDICATOR

LED

CHANNEL

SELECTOR

4.7in/120mm

1.8in/45mm

TELIS 4 RTS

4 INDIVIDUAL CHANNELS

& 1 MASTER CHANNEL

BACK

PROGRAMMING

BUTTON

SIDE

0.7in

mm

/17

PROGRAMMING

BUTTON

SIDE

The LT RTS CMO is designed for rolling blinds, awnings, and shutters.
The LT RTS CMO must be programmed with the Inteo family of transmitters.
The LT RTS CMO motors are compatible with a SOLIRIS and EOLIS RTS SENSORS.

MOTOR WIRING

COLOR CODE

120 VAC

CODE

BLACK

WHITE

GREEN

HOT

NEUTRAL

GROUND

A. All wiring must conform to NEC (National Electrical Code) and local codes.

B. The LT RTS CMO motors can be wired in PARALLEL.

A means of disconnecting the power at each motor independently should
be provided.

C. Power only needs to be supplied to the motor. The receiver is completely

enclosed inside the motor tube.

D. The antenna is internal to the motor.

E. SOMFY Reserves the right to void the motor warranty if wiring

recommendations are not followed.

120

V

A

C

60

Hz

NEUTRAL

GROUND

GREEN

WHITE

HOT

BL

ACK

Programming and Limit Setting Instructions

LT RTS CMO MOTOR

EOLIS SENSOR RTS

PROGRAMMING

BUTTON

-

+

-

+

Important Installation Tips

Summary of Contents for LT RTS CMO

Page 1: ... an awning it will open or extend the awning If the UP button extends the awning the wind sensor will also extend the awning during windy conditions THIS IS DANGEROUS Damage and injury could occur Do not proceed until proper operation of the transmitter is verified 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total of 5 channels ...

Page 2: ... POWER ON FOR FIRST TIME 1 Two positions have to be set the UP and DOWN limits This is achieved with the mechanical CMO limit switch unit Provide power to the motor Notice the motor will not respond to any transmitter until a transmitter is assigned to communicate with the motors receiver A Remove the protective cap covering the limit setting buttons on the motor head replace when finished B Depre...

Page 3: ...USLY UP DOWN pressed and held LT RTS CMO LT RTS CMO refer to the Warning note in Section LT RTS CMO LT RTS CMO Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor The motor is now in USER MODE Press the programming button on the RTS transmitter User Mode This mode is for operating the motor by the end user Two intermediate postions...

Page 4: ...indicating that the LT RTS CMO motor has memorized the second intermediate position IP2 2 Record the INTERMEDIATE POSITION IP2 referenced from the DOWN LIMIT of the end product REACH THE INTERMEDIATE POSITIONS DELETE AN INTERMEDIATE POSITION The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor is in a programming state The end product jogs briefly UP DOWN indicating that the t...

Page 5: ...Resetting the motor s memory and recording a new transmitter when the only transmitter is lost A Perform a power cut in the following sequence 1 Power off 2 sec Minimum 2 Power on 5 to 15 seconds 3 Power off 2 sec minimum 4 Power on The end product moves for 5 seconds in one direction to indicate that the double power cut has been recorded The motor is in INSTALLER MODE for 2 minutes WARNING This ...

Page 6: ...ODE and return to USER MODE RESETTING MOTORS BACK TO USER MODE B Press more than 5 seconds on the programming button of the PREVIOUSLY recorded RTS transmitter channel The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor has been completely cleared NOTE A double power cut cannot be achieved if the motor is still in FACTORY or INSTALLER Mode First program a transmitter into the...

Reviews: