66
© 2011 Somfy SAS. All rights reserved. 11/2011
EN
5.5.
Programming the first Somfy io local control point
5.5.1. Using a pre-programmed Somfy io local control point
(5.2)
Briefly press the
PROG button
on this control point:
the blind
moves briefly, the control point has been
programmed.
5.5.2. After a power cut
•
Press the
Up and Down buttons
on the new control point
simultaneously until the blind moves.
• Briefly press the
PROG button
on this control point:
the blind
moves briefly; the control point has been
programmed.
5.6.
Checking the settings
Check the settings of the upper and lower end limits using the Somfy io local control point.
5.4.2. Modifying the angular travel
For optimum operation of the J4 io actuator, it is
essential to adjust the angular travel.
The angular travel is the total angle necessary for the
blind to change from a slats closed position to a slats
fully open position.
The slats fully open position is reached when the slats
no longer tilt and the blind makes an initial raising
movement.
•
Press the
down button
until the lowered position is
reached.
•
When the blind is in the lowered position, press the
Up
and Down buttons for 5 seconds
: the blind moves
briefly.
•
Press the
"my" button
on the control point: the blind
moves briefly.
•
Move the slats from the slats closed position to the slats
fully open position by briefly pressing the Up button on the
control point.
•
Press the
Up button and "my" buttons
on the control
point at the same time, until the blind moves.
or
or