5. COMMISSIONING
Programming the first
Somfy local control
point
Only one motor should be powered at a time.
Switch on and follow procedure "a" or "b"
depending on the reaction of the blind:
a) The blind moves briefly
The end limits are set and no
Somfy control point has been stored.
Go to the section entitled 5.5 "Programming the first
Somfy io local control point".
or
b) The blind does not move
Press the
Up or Down buttons
and follow
procedure "c" or "d" depending on the reaction of the
blind:
c) The blind still does not move
The end limits are not set and no
Somfy control point has been stored.
Go to the section entitled 5.2 "Pre-programming the
Somfy io local control point".
or
d) The blind is fully raised or lowered
The end limits are set and the
Somfy control point has been stored.
Go to the section entitled "Operation".
5.2. Pre-programming the Somfy io local control point
The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point
which provides greater precision when tilting the slats.
For commissioning using any other io control point, refer to the corresponding guide.
5.1. Identifying setting steps already completed
•
Press the
Up and Down buttons
simultaneously.
The blind
moves briefly, the Somfy local
io control point is pre-programmed to the motor.
Pre-programming the
Somfy io local control
point
Operation