Installation Instructions
Power supply :
Rated Current :
Operating temperature : -4
24V AC/DC
25 mA at 24V DC
The
must be supplied by a class 2 transformer
EOLIS RTS
0
sensor
F to +122 F/-20 C to +50 C
0
0
0
24V EOLIS RTS SENSOR KIT
CAT NO. 6301050
(Includes transformer, not shown)
The
is a radio wind sensor for awnings
The wind threshold can be set directly on the
The
is compatible with the
and
motors only.
EOLIS RTS
EOLIS RTS
.
RTS
LT RTS CMO
ALTUS RTS
sensor
sensor
EOLIS
sensor
Installation
1
Dimensions
9.3 in./236 mm
6.3
in./160
mm
x
x
x
x
x
x
SOMFY SYSTEMS, INC. reserves the
right to update, change or modify
these instructions without prior notice.
REF. NO: 182450A
COPYRIGHT C SOMFY SYSTEMS, INC.
4/02
SOMFY SYSTEMS, INC.
47 Commerce Drive
Cranbury, NJ 08512
SOMFY CANADA
6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2
SOMFY MEXICO S.A. De C.V.
Calle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex C.P. 53370
inteo
EOLIS RTS
24V
sensor
Wiring
2
1. Remove Cover and unscrew
plate over wiring compartment
UP
STOP
DOWN
2. Loosen the strain relief
plate and guide the power
supply wires through
the black grommet into
terminal block
3. Connect the cable leads to the terminals
- Terminal block is removable for
easier connections and the input power
is not polarized.
WARNING:
For the
to function properly, the
transmitter which is memorized into the motor's receiver, must be
configured correctly. The DOWN button MUST correspond to
DOWN on the end product. In the case of an awning, it will open
or extend the awning. If the UP button extends the awning, the
wind sensor will also extend the awning during windy conditions.
THIS IS DANGEROUS! Damage and injury could occur. Do not
proceed until proper operation of the transmitter is verified.
Please refer to the installation instructions of the relevant motor
to change the direction if necessary.
EOLIS RTS SENSOR
grommets
strain
relief
TO 24V AC/DC
TRANSFORMER
TO 24V AC/DC
TRANSFORMER
x
x
4. Replace wire
compartment cover
5. Attach the sensor to the wall.
Replace front cover and secure
with screws provided
A. Power input to the sensor is not polarized,
but turn off the power and fully discharge
the transformer before making final connections.
B. The cable distance between the power supply
and the sensor must not exceed 164 feet.