background image

Installation Instructions

Power supply :
Rated Current :

Operating temperature : -4

24V AC/DC

25 mA at 24V DC

The

must be supplied by a class 2 transformer

EOLIS RTS

0

sensor

F to +122 F/-20 C to +50 C

0

0

0

24V EOLIS RTS SENSOR KIT

CAT NO. 6301050

(Includes transformer, not shown)

The

is a radio wind sensor for awnings

The wind threshold can be set directly on the
The

is compatible with the

and

motors only.

EOLIS RTS

EOLIS RTS

.

RTS

LT RTS CMO

ALTUS RTS

sensor

sensor

EOLIS

sensor

Installation

1

Dimensions

9.3 in./236 mm

6.3

in./160

mm

x

x

x

x

x

x

SOMFY SYSTEMS, INC. reserves the
right to update, change or modify
these instructions without prior notice.

REF. NO: 182450A

COPYRIGHT C SOMFY SYSTEMS, INC.

4/02

SOMFY SYSTEMS, INC.

47 Commerce Drive
Cranbury, NJ 08512

SOMFY CANADA

6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2

SOMFY MEXICO S.A. De C.V.

Calle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex C.P. 53370

inteo

EOLIS RTS

24V

sensor

Wiring

2

1. Remove Cover and unscrew
plate over wiring compartment

UP
STOP
DOWN

2. Loosen the strain relief
plate and guide the power
supply wires through
the black grommet into
terminal block

3. Connect the cable leads to the terminals
- Terminal block is removable for

easier connections and the input power
is not polarized.

WARNING:

For the

to function properly, the

transmitter which is memorized into the motor's receiver, must be
configured correctly. The DOWN button MUST correspond to
DOWN on the end product. In the case of an awning, it will open
or extend the awning. If the UP button extends the awning, the
wind sensor will also extend the awning during windy conditions.
THIS IS DANGEROUS! Damage and injury could occur. Do not
proceed until proper operation of the transmitter is verified.
Please refer to the installation instructions of the relevant motor
to change the direction if necessary.

EOLIS RTS SENSOR

grommets

strain
relief

TO 24V AC/DC
TRANSFORMER

TO 24V AC/DC
TRANSFORMER

x

x

4. Replace wire
compartment cover

5. Attach the sensor to the wall.
Replace front cover and secure
with screws provided

A. Power input to the sensor is not polarized,
but turn off the power and fully discharge
the transformer before making final connections.
B. The cable distance between the power supply
and the sensor must not exceed 164 feet.

Reviews: