background image

We reserve the right to make changes due to technical improvements. 

CENTRALIS uno RTS VB

2

GROUP CONTROL (one transmitter for several receivers)

To program one control in several 

CENTRALIS uno RTS VB

, set all the receivers in their programming mode then repeat the same procedure.

It is recommended not to use a RT control as a general control point.

To record several RTS controls in CENTRALIS uno RTS VBrepeat the same procedure as described in section 3.1 for each control.

You can also use an already recorded control to set the 

CENTRALIS uno RTS VB

in its programming mode

RTS control :

press for more than 2 sec. on the “prog” button.

RT control :

remove the battery, press briefly the button, replace the battery and press for more than 2 sec. on the button.

The LED of the 

CENTRALIS uno RTS VB

lights on and the blind jogs briefly UP and DOWN indicating that the 

CENTRALIS uno RTS VB

is in programming mode and that you can record a new control.

You can program up to 12 controls to one receiver.  If you try to enter a 13th, your instruction will be ignored.

CENTRALIS uno RTS 

can be operated by its push-buttons or with a RT/RTS control.

CENTRALIS uno RTS VB

offers two different modes to control the venetian blind.

P

R

O

G

MAINS

230V - 50Hz

3 wires x 1,5 mm

2

4 wires x 0,75 mm

2

Neutral

Earth

Phase

1 2 3 4 5 6

5 wires x 1,5 mm

2

N

L

N

Centralis uno RTS

Junction box

Motor

Supply

Phase
Neutral
Earth

Earth 

(green/yellow)

Common 

(blue)

Up 

(black or brown)

Down 

(black or brown)

L

N

N


1
2
3
4
5
6

N

L

N

SUPPLY

230V 50Hz

Phase

Neutral

Earth

LT motor

DOWN

PE

N

UP

• disconnect mains before carrying out any work.

• ensure that no forces act on the screw terminals after installation.

3

Radio programming

Set the 

CENTRALIS uno RTS VB

in

its programming mode by pressing the
PROG button until the blind jogs briefly
(UP/DOWN).

The 

CENTRALIS uno RTS VB

will

remain ready to record a control for two
minutes.

P

R

O

G

2 sec.

3V

LITHIUM

RENA

TA

CR 2032

3V

LITHIUM

RENA

TA

CR 2032

S

W

IS

S

M ADE

3V

LITHIUM

RENA

TA

CR 2032

3V

LITHIUM

RENA

TA

CR 2032

S

W

IS

S

M ADE

0,5 s

0,5 s

0,5 s

We reserve the right to make changes due to technical improvements. 

3

CENTRALIS uno RTS VB

Press the prog button of the 

CENTRALIS uno RTS VB

to enter in programming mode, then press shortly the prog button of the RTS

control you wish to remove.
It is also possible to set the 

CENTRALIS uno RTS VB

in its programming mode with another RTS control (see 3.2), then press

shortly the prog button of the RTS control you wish to remove.

To remove all the controls, do a complete reset of the 

CENTRALIS uno RTS VB

(see section 5).

4

Operating

“auto” position :

All commands from the push buttons of the 

CENTRALIS uno RTS VB 

(local control) and from the radio

controls (master control) are taken into account.

“0” position :

Only the push button commands are taken into account and the radio commands are disabled (This feature
allows to isolate a room from the master control). To force the control of the CENTRALIS uno RTS VB with
radio, the radio command should be longer than 2 sec.

In association with the 

SOLIRIS/EOLIS sensors RTS 

or a 

CHRONIS RTS light

,

CENTRALIS uno RTS VB 

is able to control and protect the blind according to the sun

and wind conditions.
To record a 

SOLIRIS/EOLIS RTS

sensor or a 

CHRONIS RTS light

in the 

CENTRA-

LIS uno RTS VB

, repeat the same procedure as describe in section 3.2 (record a new

control).
Refer to the instruction manual of the relevant products for the programming and set-
ting procedures.

The blind jogs briefly (UP/DOWN)

and the LED of the 

CENTRALIS

uno RTS VB

blinks during 5 secs.

indicating that the control has been
recorded.

CENTRALIS uno RTS VB

quits its

programming mode.

RTS control

Press briefly the program-
ming button on the RTS
control you wish to record.

RT control

Remove the battery, press
briefly the button, replace the
battery and press again briefly
the button.

UP/DOWN/STOP/TILT commands

4.1

0/auto switch

4.2

Wind/Sun/Light functions

4.3

Remove a control (on an existing installation)

3.3

Initial installation : record the first control

3.1

Record new controls

3.2

Wiring

2.2

US mode (factory mode) 

§

Press briefly the 

or 

buttons to raise or lower the blind.

§

Press briefly the 

button To stop the blind.

§

To tilt the slats, press and hold the 

or 

buttons.

If you hold the control buttons for more than 6 seconds, the blind 
will start to move continuously up to its end limits.

EU mode :

§

To raise or lower the blind, press and hold more than 2 secs. the 

or 

buttons.

§

To stop the blind, press briefly the 

button.

§

To tilt the slats, press briefly the 

or 

buttons.

UP button

0/auto switch

STOP/IP button

DOWN button

The configuration can be changed by pressing for more than 5 secs. on the 

button of a RTS control just after the power on. The

blind jogs, indicating that 

CENTRALIS uno RTS VB

has changed the configuration.

With the 

CENTRALIS uno RTS VB

, it is possible to program an automatic intermediate position (IP) and an automatic tilting of the

slats. You can choose to program one or the other, or both. The recording of the intermediate position and the tilting can be made
from the 

CENTRALIS uno RTS VB

or from a RTS control.

Intermediate position / automatic slat tilting

4.4

1

2

Reviews: