DRSS-1080
Digital Signal Splitter
Installation and Operation
5-3
Source Stream
Two parallel connectors are provided for the original (source)
Stream.
One connector can be used as the input and the other as a
pass-through output.
The design ensures that there is no interruption of the source
bitstream when the Splitter is unpowered.
Termination
For compatibility with ITU G.703 specifications, streams
should be terminated with a 75 load.
The input is internally terminated with 40 k , hence the
need to use the supplied external 75 terminator on the
unused Source connector when a down-stream device is
not connected.