I2773-4.
4
en
85
Somat eDAQ
lite
Example PC Message Channel Files
•
ASCII Message Channel:
# msg_ascii@simmsg_asc.RN_1 (Sim Msg simmsg_asc)
RX 10.0000000: 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57
58 59 5A 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51
(and so on...)
RX 20.0000000: 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57
58 59 5A 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51
(and so on...)
•
Binary Message Channel:
# msg_bin@simmsg_bin.RN_1 (Sim Msg simmsg_bin)
RX 4.0000000: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16
17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B
(and so on …)
RX 8.0000000: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16
17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B
(and so on …)
Generate Quickview Log File (SIF only)
The generate quickview log file option parses the SIF file channel list and generates
an ASCII log file that summarizes the channel list with presentation of some of the
channel header information combined with a small amount of the actual data for each
channel. This option is provided primarily for troubleshooting corrupt SIF data files.
4.7
Using Remote Control Operation
Start and stop test runs remotely using the remote control operational mode. The
remote control mode uses digital I/O lines for control inputs and status outputs. The
eDAQ
lite
uses the digital lines on the lowest addressed ELDIO layer (i.e., DIO_1).
Use one digital input line to control test run starts and stops and up to four digital output
lines for status indications. Configure the digital input and output line assignments in
the TCE Remote Control Preferences dialog.
The remote control mode is enabled at test initialization and remains in effect until the
test ends, unless manually suspended. When the remote control mode is active, many
of the test control tasks are disabled.
The Remote Control Setup preferences configure the eDAQ
lite
for remote control of
test runs using digital input and output lines. For more information or remote control
preferences, see
“Remote Test Run Control” on page 54
.
HBM: public
Summary of Contents for eDAQlite
Page 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Page 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Page 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Page 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Page 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Page 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Page 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Page 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Page 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Page 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Page 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...