7. Cleaning and Maintenance
* You should remove ash from the pan on a regular basis (after the unit is
switched off), so that the combustion air is not prevented from entering through
the ash grate;
* The baffle plate (removable plate in the ceiling of the combustion chamber)
should be removed and cleaned on a regular basis, according to use, as it
gathers ash and may impede the draught;
* To clean the glass, you need to place the key in the lock located in the centre
of the top edge of the door. Rotate the lock to the left, which will then allow you
to tilt the door forwards (see Fig. 9);
* The glass should only be cleaned when completely cold;
* The glass should be cleaned with a suitable product,
4
by following the
instructions for use and not allowing the product to come into contact with the
sealing string and painted metal parts, which could initiate oxidation. The sealing
string is glued, so should not be moistened with water or cleaning products. If it
becomes detached, it can be reattached with contact glue after cleaning the
groove with fine sandpaper;
* Do not clean the plate iron parts with detergent, but rather with just a dry cloth
to remove the dust;
* We advise you to clean the flue and flue throat (at the exit of the unit) at least
once a year, removing the baffle plate to do so;
* If you do not use the unit for a prolonged period, check to make sure that the
flue pipes are clear before lighting it.