![SOLZAIMA Trevi 1100 Instruction Manual Download Page 11](http://html.mh-extra.com/html/solzaima/trevi-1100/trevi-1100_instruction-manual_1317231011.webp)
11
Check the ventilator is working, if applicable, as well as the installation of the adjustable
legs. Remove the label from the glass and retain the instruction manual for future
reference.
1. Combustion air and gas circulation
*
This type of unit should be installed in a well-ventilated area. Any air intake
grilles should be placed in locations that are not liable to become blocked;
* The combustion air enters the stove through a set of easily visible openings,
located on the front of the fire. This flow should be kept clear at all times;
* Additional air inlets may be needed if the stove is used in simultaneous with
other devices that require an air supply. The installer should evaluate the
situation according to the overall air flow requirements;
* Under normal operating conditions, the combustion gas flow should create a
draught of 12 Pa one metre above the throat of the flue. For proper installation,
at least 78.7 inches (2 metres) of metal flue tube with the same diameter as the
unit's smoke outlet should be fitted vertically above the unit. After this section,
sections of tubing with a maximum angle of 45° may be used; Figures 10 and 11
illustrate correct and incorrect angles for installing a bend;