background image

15

Exploded View

No

Description

Part Number

1

Remote Control

2203001

2

Front Glass

2203011

3

Side Glass

2203016

4

Flame Screen

2203020

5

Blower and Heater Assembly

2203050

6

Power Supply Board

2203002

7

Main PCB Board

2203052

8

Fuel Bed LED

2203044

9

Flame LED

2203041

10

Synchronous Motor

2203047

11

Flame Effect Drum

2203082

12

Front Log

2203032

Replaceable Parts

Summary of Contents for SLE42s

Page 1: ...4 108 EC The complete installation must be carried out in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance I...

Page 2: ...n Fuel Bed Brightness Operation Flame Brightness Operation Setting the Time and Day 24 Hour Clock Setting the Weekly Timer Thermal Safety Cut Out Light Emitting Diode Battery Replacement Remote Contro...

Page 3: ...switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility CAUTION Some parts of this appliance around the heater grill can become very hot and ca...

Page 4: ...nce shall not be carried out by children without supervision Children of less than 3 years should be kept away from the appliance unless continuously supervised Children aged from 3 years to 8 years s...

Page 5: ...2 Fig 3 Fig 4 Locating the Unit Before commencing installation of the unit consideration should be given to the following 1 Position in the area to be heated central locations are usually best 2 Allow...

Page 6: ...r Heater 12W Gross Weight kgs 45kg Efficiency Rating A Commissioning and Handover On completion of the installation Ensure that the operating instructions for the unit are left with the customer Ensur...

Page 7: ...eat output elmax N A kW Type of heat output room temperature control select one At minimum heat output elmin N A kW single stage heat output and no room temperature control no In standby mode elSB 0 3...

Page 8: ...inate when the fire is plugged in the wall socket switch is on and the manual on off switch is on The red light will remain illuminated for 10 seconds to show there is power to your fire Remote Contol...

Page 9: ...above the room temperature for the heating function to operate Fig 23 Heater Operation Press the Heater button to select Full Heat 2000W and H02 with the flame symbol will be displayed see Fig 23 Pres...

Page 10: ...can also be adjusted by pressing the Brightness button to select from the following levels see Fig 26 H High Maximum Setting C Central Intermediate Setting L Low Minimum Setting NOTE Icon flashes on...

Page 11: ...on 2 Press and hold the Timer Mode button for two seconds to enter the timer settings 3 Press the Time Setting button to select the day to programme 4 The settings for the 1st ON OFF period 1 for Mon...

Page 12: ...ty cut out is incorporated in the heater to prevent damage due to overheating This can happen if the heat outlet is restricted in any way The heater will switch on once the obstruction has been remove...

Page 13: ...lluminated Check the flame effect and fuel bed lights have not been turned off from the remote Please refer to your retailer if your fire is not operating correctly after re reading these instructions...

Page 14: ...s can be ordered from www solutionfires co uk or directly from a Solution Fire Retailer Items considered as consumable such as glass screens bulbs LED boards ceramic logs fuses and batteries which are...

Page 15: ...2203011 3 Side Glass 2203016 4 Flame Screen 2203020 5 Blower and Heater Assembly 2203050 6 Power Supply Board 2203002 7 Main PCB Board 2203052 8 Fuel Bed LED 2203044 9 Flame LED 2203041 10 Synchronous...

Page 16: ...Wiring Diagram www solutionfires co uk info solutionfires co uk Capital Fireplaces Units 12 17 Henlow Trading Est Henlow Bedfordshire SG16 6DS...

Reviews: