Gas Shut Off
All Fire pits must have a gas shut-off mechanism located outside of the appliance. This gas shut-off
mechanism must be accessible for emergency shut-off and maintenance. Please note that the Key
Ball Valve outside the vessel of this firepit is not a shut-off mechanism. This Key Ball Valve is used
to regulate the flame height and flame intensity.
Electrical Shut Off
All Fire pits with electronic ignitions must have an External shut-off switch (ON/OFF switch or timer)
near the fire pit. This electrical switch/timer must be accessible for emergency shut-off and
maintenance.
Timer must have a Manual ON/OFF Button.
Please refer to the local electrical and
building codes prior to installation of the switch.
FIRE PIT CLEARANCES
Horizontal Clearance
Concrete vessels must be at least 16 inches (0.5 meter) away from any combustible structure and/or
materials.
Vertical Clearance
Clearance between the burner and any structure overhead must be at least 77 inches (1.95 meter)
from any combustible structure and/or materials.