This fire pit conform to the following standards:
ANSI
Z21.97 – 2004 / CSA 2.41 -2017
Outdoor Decorative Gas Appliance
CSA
2.17-2017
Gas-Fired Appliances For Use at High Altitudes
CE
BS EN 498:2012
Specification for Dedicated Liquefied Petroleum Gas Appliances
CE
BS EN 509:2001 + A1 : 2003 + A2: 2004
Decorative Fuel-Effect Gas Appliances
Made in Canada by Solus Decor Inc.
Building C-109 Braid Street, New Westminster, BC Canada V3L5H4
1.877.255.3146
PRODUCT RATINGS
GAS RATINGS
Natural Gas (NG)
Inlet Gas Pressure
:
7 ”W.C. (17.4mbar) (0.25 PSi)
Manifold Gas Pressure
:
Burner Ratings
Minimum Manifold Pressure Requirement
60,000 BTU (17.58kW)
3.5”W.C. (8.7mbar) (0.12 PSi)
73,500 BTU (21.39kW)
3.5”W.C. (8.7mbar) (0.12 PSi)
108,000 BTU (31.65kW)
2.5”W.C. (6.2 mbar) (0.09 PSi
ELECTRICAL RATINGS
North America
: 120vAC, 60Hz, 1.5 Amp
Operating Ranges : 108vAC - 132vAC
UK/EU :
230vAC, 50Hz, 1.5 Amp
Operating Ranges : 220vAC - 240vAC for
UK/EU
WARNINGS:
Consistent
Inlet Gas Pressure
is required to avoid weak pilot flame and burner dropouts.
Stable
Voltage Supply
is required to avoid ignition module lockout.
Page 2 of 32