ROUTINE AND EXTRAORDINARY MAINTENANCE
To keep the solarium efficient, carry out the following simple operations:
The unit has to be disconnected from power supply before cleaning acrylics or lamps or
engaging in the maintenance of the product.
Clean the lamps with specific products for cleaning glass surfaces.
Clean the acrylic without using detergent products containing alcohol (the surface could become dull
and therefore stop a part of the UV).
Various suitable products are readily available on the market for this purpose.
Clean the equipment (especially the parts in contact) with non-aggressive disinfectant products.
Various suitable products are readily available on the market for this purpose.
Periodically make sure that the air intakes are not blocked with dust or other materials (tissues, etc.).
Periodically replace the lamps and the starters (normally between 400 and 600 hours of use).
For replacing lamps and starters:
•
Disconnect the unit from power supply;
•
Unscrew and remove the 2 screws on the upper side of one acrylic panel and remove the
metal cover;
•
Unscrew (without removing) the 2 screws on the lower side of the acrylic panel;
•
Lift up the acrylic from screws and store in a safe place to avoid damage;
•
Remove the lamps by turning them 90° and pulling out from lamp holders;
•
Install new lamps by repeating the same operations in reverse.
•
Clean lamps and acrylics before closing the panel;
•
Power the tanning system on after completing the process.
All operation that access electrical parts have to be completed by a qualified technician.
Before accessing inside the unit disconnect power supply
.
For replacement of lamps, eyewear or parts, contact:
JK Products and Services
1, Walter Kratz Drive
Jonesboro, AR 72401
(877) 786 5267
22