8. SPECIFICATIONS: 

Specifications for long run models SS-750L/1000L/1500L/2000L: 

MODEL / CAPACITY

 

SS-750L 

(750VA)

 

SS-1000L 

(1000VA)

 

SS-1500L 

(1500VA) 

SS-2000L 

(2000VA) 

Continuous Loading 

500W 700W 900W 1200W 

Max. Loading 

750W 

1000W 

1500W 

2000W 

 

(< 30sec.) 

(< 30 sec.) 

(< 30 sec.) 

(< 30 sec.) 

INPUT Voltage 

Frequency Selectable 

100/110/115/120V 1ø or 200/220/230/240V 1ø 

50Hz/60Hz Auto detect 

Current (110V/220V) 

8A / 4A 

10A / 5A 

16A / 8A 

20A / 10A 

Voltage  100/110/115/120V 1ø or 200/220/230/240V 1ø 

±

3% for Back-up Mode 

 

 

±

10% for AVR 

Frequency  50Hz or 60Hz ± 0.1Hz (Selectable under DC start) 

OUTPUT 

Wave Form  True Sine Wave 

Current (110V/220V) 

6.8A / 3.4A 

9.1A / 4.6A 

13.6A / 6.8A 

18.2A / 9.1A 

TRANSFER TIME 

Transfer Time 

 

3 ms 

BATTERY      

Voltage 

36V 

48V 

48V 

72V 

 

24V (optional)

36V (optional)

 

 

Level Ind. 

YES 

YES 

YSE 

YSE 

Protection for reverse battery 

polarity 

YES YES YES YES 

CHARGE 

Voltage  40.95V / 27.3V

54.60V / 40.95V

54.60V 

81.90V 

Maximum 

Current 

6A 6A 6A 6A 

LED / ALARM INDICATION 

LED Alarm 

Normal city power  GRN Lighting 

No beep 

Back up Mode  ORG Flashing 

B-B-----B-B----- (2 beeps/4sec.) 

Abnormal Freq. of City power 

(Frequency > 65Hz or < 47Hz) 

ORG Flashing (quick) 

B-B-----B-B----- (2 beeps/4sec.) 
(Transfer to backup mode) 

Abnormal Voltage of City power 

(Voltage > 126% or < 77%) 

ORG Flashing (slow) 

B-B-----B-B----- (2beeps/4sec.) 
(Transfer to backup mode) 

Low Battery Alarm  ORG Flashing 

B-B-B-B-B-B-------- (4 beeps/sec.) 

Battery Fail Alarm  RED Flashing 

B

B

B

B

B

B

B

..

 (8 beeps/sec.) 

Over load Alarm  RED Lighting 

B……….. (continuously) 

Thermal Alarm  RED Flashing 

G

....

.  R

....

.  

(G = 16beeps/2sec. R = silence / 2sec.) 

LOAD LEVEL INDICATION 

YES 

YES 

YES 

YES 

DC START / ALARM RESET 

YES 

YES 

YES 

YES 

RS-232 

INTERFACE 

YES YES YES YES 

ENVIRONMENT TEMP. 

0 - 37 

 

ENVIRONMENT HUMIDITY 

30-95% Non-Condensing 

DIMENSIONS (L x H x W) 

45 x 20 x 18 (cm) 45 x 20 x 18 (cm) 45 x 20 x 18 (cm)  45 x 20 x 18 (cm)

SHIPPING DIM. (L x H x W) 

54 x 33 x 30 (cm) 54 x 33 x 30 (cm) 54 x 33 x 30 (cm)  54 x 33 x 30 (cm)

WEIGHT (N.W. / G.W.) 

13.0/14.0 kgs 

14.5/15.5 kgs 

17.5/18.5 kgs 

17.5/18.5 kgs 

Summary of Contents for SS-1000L

Page 1: ...UPS AVR Uninterruptible Power System User s Manual Line Interactive Sine Wave Long backup models SS 750L 1000L 1500L 2000L 100 80 60 40 20 NORMAL BACK UP LOW BATT OVER LOAD BATTERY LOAD...

Page 2: ...4 2 Operation 4 3 Connecting the FAX machine 5 INDICATION AND CONTROL Page 7 8 5 1 Battery level and load level LEDs 5 2 Operation status LED 5 3 Audible alarm 5 4 Auto self test function 5 5 DIP swit...

Page 3: ...FRONT PANEL FOR ALL MODELS LEDs of battery voltage level and load level LED of operation status Control button 2 1 3 100 80 60 40 20 3 1 2 NORMAL BACK UP LOW BATT OVER LOAD BATTERY LOAD...

Page 4: ...1000L 1500L 2000L only Rear Panel Fuse Inlet of city power Outlets NEMA IEC RS 232 Interface DIP switch Phone jacks for fax machine optional by DIP switch Battery connector 1 6 5 4 2 1 2 3 4 5 6 3 3...

Page 5: ...are provided to maintain the batteries in the best condition 1 2 Battery replacement warning The self test function by pushing the button will inform you with an alarm when the batteries are weak and...

Page 6: ...devices such as monitors modems external H Disk drivers etc To ensure the performance of the UPS Do Not load the UPS with laser printer motor or any type of inductive load Connecting the UPS to a two...

Page 7: ...rging please pull out the power cord to shut down the UPS completely 4 2 3 During a blackout push the button for entering idle mode Ref Indication Table then push again for one second and the UPS will...

Page 8: ...e the beeping can be silenced by pushing the button However the warning of low battery will still sound for urging user to leave computer without any data loss Basic Indication Table LED ALARM PERIOD...

Page 9: ...l The UPS can be set for daily shutdown wake up This command must be set through the RS 232 interface When this function is set the timer inside the UPS will begin to run and the load will be turned o...

Page 10: ...Rx In 6 2 The definition and setup for DB9 optional is as following Pin 2 AC Power Failure Pin 4 Common GND of Pin 2 Pin 5 Pin 5 UPS Battery Low Pin 6 Turn off UPS Pin 7 GND of Pin6 The interface with...

Page 11: ...ot provide expected run time 1 Excessive loads connected at UPS outlets 2 Battery is weak and can not provide enough capacity Do not operate the UPS and leave the UPS plugged in for 10 hours Then test...

Page 12: ...ge 40 95V 27 3V 54 60V 40 95V 54 60V 81 90V Maximum Current 6A 6A 6A 6A LED ALARM INDICATION LED Alarm Normal city power GRN Lighting No beep Back up Mode ORG Flashing B B B B 2 beeps 4sec Abnormal Fr...

Page 13: ...is about 5 min German wording Wenn Sie die Batterien austauschen verwenden Sie bitte die gleiche Anzahl und den gleichen Batterietyp Werfen Sie niemals die Batterien in das Feuer die Batterien k nnte...

Reviews: