5 Safety provisions 

 

5.1  Intended use / applications 

 

The foam sprayer must only be used to apply the 
cleaning agents and disinfectants described below 
that are suitable for foaming.  
Strictly observe the guide lines provided by the 
chemical manufacturer.  
The foam sprayer of the model series 

A

  

- type 

309 FA

 (FKM seals) is suitable for 

application of acidic to pH-neutral spraying agents 
in the 

pH range of 1 – 7

 

The foam sprayer of the model series 

B

  

- type 

309 FB

 (EPDM seals) is suitable for 

application of pH-neutral to alkaline spraying 
agents in the 

pH range of 7 – 14

 

The pressure sprayer must 

not 

be used for all 

purposes not named above, such as  

- spraying of paints 
- distribution of  
 * 

flammable 

liquids 

 

* sticky, residue-forming agents 

 * 

surfactants 

 

* fluids with temperatures  

 

  above 40  C [104 °F] 

 

* agents not intended for distribution by 

 

  foam sprayers 

and  
- storage of fluids!  

5.2  General safety notes 

 

Read the original instructions before first use and 
keep it in a safe place.  
Non-observation of information provided in these 
original instructions may potentially be fatal; the 
user is liable for any damage, direct or 
consequential, caused by this. 
The original instructions must be kept on hand at 
the site of use of the sprayer at all times.  
It must be read by all who are charged with any 
work with and on the device (including for 
maintenance, care and repair). 

x

 

Have safe use shown and explained to you by a 
SOLO specialist vendor. 

x

 

Persons under the age of 18 must only work 
under supervision with this sprayer.  

x

 

Keep persons and animals away from the 
working area. Never spray in the direction of any 
persons, animals or objects that could be hurt or 
damaged.  

x

 

This sprayer must only be passed on to persons 
who are familiar with this model, its operation 
and the original instructions. 

x

 

If you work with this sprayer, you should be 
physically fit, rested and healthy.  

x

 

Do not use the sprayer while under the influence 
of alcohol, drugs or medication. 

 

x

 

Never make any changes to existing safety 
provisions and operating parts.  

x

 

Only use the sprayer when it is operationally 
safe to do so. Check the sprayer before every 
use according to chap. 6.2. 

x

 

Replace damaged parts without delay. Only use 
SOLO genuine spare parts.  

x

 

Only use factory approved accessories and 
attachments for this sprayer. 

x

 

Empty and clean the sprayer according to the 
information in chap. 9.2 for this. Prevent 
unauthorised access to the machine.  

5.3  Safe handling of spraying liquids 

 

x

 

Follow suitable procedures and use collection 
containers to prevent any contamination of the 
environment, the public waterways and/or storm 
water systems from chemical agents and 
cleaners. This can happen while mixing, filling, 
using, emptying, cleaning or during transport. 

x

 

Always collect chemical spray liquids and 
cleaners (including residues) in suitable 
containers and return them to collection points 
specified by the municipal administration. 

x

 

In case of skin or eye contact, rinse or flush the 
affected body parts with plenty of clean water. 
Seek medical advice without delay. 

x

 

Contaminated clothing should be changed at 
once.  

x

 

Never eat or drink while handling spray liquids 

x

 

If you feel nauseous during work, or if you are 
excessively fatigued, stop working at once. If the 
condition persists, seek medical advice without 
delay. 

x

 

Never permit children or persons work with or 
handle spraying liquids if they are not familiar 
with these substances.   

x

 

Never fill different spray solutions into the spray 
tank.  

x

 

When changing the spray solution, clean the 
spray tank and all parts that come in contact with 
the spray solution. Operate the sprayer with 
clear water first before filling the spray tank with 
the different spray solution. 

x

 

At the end of work, empty and clean the sprayer 
according to chap. 9.2, clean your face and 
hands thoroughly, take off work clothing and 
wash it regularly. 

5.4  When transporting the sprayer 

 

x

 

The device must be securely strapped down 
when transported on vehicles. 

x

 

Prevent leakages of spraying agents. The liquid 
tank of the sprayer and all liquid carrying hoses 
must be inspected regularly for leaks.   

Summary of Contents for CLEANLINE 309 FA

Page 1: ... návod k obsluze Originalna navodila za uporabo Original bruksanvisning Originalna uputa za uporabu Az eredeti üzemeltetési útmutató fordítása T umaczenie oryginalnej instrukcji eksploatacji Originalbruksanvisning Schaumsprüher Foam sprayer Pulvérisateur de mousse Pulverizador de espuma Formaschiuma Schuimsproeier P nový post ikova Razpršilec za peno Skumsprøyte Prskalica za pjenu Habpermetez Pian...

Page 2: ...Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 ...

Page 3: ...Fig 2 Fig 9 Fig 6 Fig 7 Fig 8 Fig 10 Fig 11 Fig 12 ...

Page 4: ...ident x Manipulations by non qualified persons or from improper repair attempts x Unauthorized modifications to the device x Use of unsuitable spare parts or non genuine spare parts x Use of unapproved chemicals or dilutions x Damage caused by use in the rental business Any warranty work must be performed by one of our authorised specialist vendors Cleaning care and standard adjustments are not ac...

Page 5: ...on x Never make any changes to existing safety provisions and operating parts x Only use the sprayer when it is operationally safe to do so Check the sprayer before every use according to chap 6 2 x Replace damaged parts without delay Only use SOLO genuine spare parts x Only use factory approved accessories and attachments for this sprayer x Empty and clean the sprayer according to the information...

Page 6: ...he threaded collar k on straight and firmly screw the spray tube f with O ring 16x3 mm hand tight onto the shut off valve e Do not use any tools Fig 1 When your work is completed the spray tube should be fitted into the holding clamp at the pump handle c Please put the foam adjustment unit g completely up 6 2 Checking for operationally safe condition Subject the foam sprayer to a visual inspection...

Page 7: ...by spraying agent spraying pressure and installed spray nozzle 8 3 Disposal of residual spray volume Residual spray volumes of less than 200 ml 6 8 oz are no longer pumped effectively If you do not want to fill in any more spraying agent and want to end spraying collect and dispose of the remaining amount according to the applicable laws and provisions Observe the information from the spraying age...

Page 8: ... brush Do not blow out the nozzle with your mouth Do not clean the nozzle with hard objects x Install all components again properly 9 3 Down periods and storage Empty and clean the sprayer according to chap 9 2 Keep the sprayer protected from sunlight in a dry frost free and secure location at a temperature of max 35 C 95 F No open fireplaces or similar must be nearby Prevent unauthorised use espe...

Page 9: ... SOLO Kleinmotoren GmbH Stuttgarter Straße 41 D 71069 Sindelfingen Postfach PO Box 60 01 52 D 71050 Sindelfingen DEUTSCHLAND GERMANY Tel 49 0 7031 301 0 Fax 49 0 7031 301 149 info solo germany com www solo germany com ...

Reviews: