17
Program Description
Selectable option & behavior
LCD setting display
1
AC input
voltage range
Wide
(default): If selected, acceptable AC
input voltage range will be within 90-
280VAC
Narrow
: If selected, acceptable AC input
voltage range will be within 170-280VAC
2
Output
source
priority: To
configure load
power source
priority
Solar first
(default): Solar energy provide
power to the loads as first priority.
If solar energy is not sufficient to power all
connected loads, battery energy will supply
power the load at the same time.
Utility provides power to the loads only
when any below condition happens:
-Solar energy is not available
-Battery voltage drop to either low-level
warning voltage or the setting point in
program 5.
Utility first
: Utility will provide power to the
loads as first priority.
Solar and battery energy will provide power
to the load only when utility power is not
available.
SbU
: Solar energy provide power to the
loads as first priority.
If solar energy is not sufficient to power all
connected loads, battery energy will supply
power the load at the same time.
Utility provides power to the loads only
when battery voltage drop to either low-
level warning voltage or the setting point in
program 5.
3
Charger
source
priority:
To configure
charger
source
priority
Solar first: Solar energy will charge battery
as first priority.
Utility will charge battery only when solar
energy is not available.
Utility first: Utility will charge battery as first
priority.
Solar energy will charge battery only when
utility power is not available.
Solar and Utility(default): Solar energy and
utility will charge battery at the same time.
Only solar: Solar energy will be the only
charger source no matter utility is available
or not.