Condenser FAN:
OFF
•
LIGHTS:
OFF
•
Display
•
Master Alarm indicator: ON (solid)
•
Main Display:
Toggles between the Regulation Sensor and “rFF”
•
Buttons:
Disabled but menu item can still be accessed
Note: Alarm is reset by cooler unplugging only.
10.2 ALARM DISPLAY CODES
Different alarms indications will be shown on the display when various faults are detected by the unit:
Alarm
Displayed Code
Probe1 Faulty
PF1
Probe2 Faulty
PF2
Probe3 Faulty
PF3
Probe4 Faulty
PF4
Door Switch Alarm
dOP
Door Switch Failure/Malfunction
dSF
Refrigeration Failure
rFF
Condenser Over Temperature
COt
Condenser Under Temperature
CUt
Ambient Over Temperature
AOt
Ambient Under Temperature
AUt
The display will cycle between the Regulation Temperature and any of the currently existing alarms. For example, if the
current temperature is 3.3, and both probe#1 & 2 are faulty, then the display will cycle between the following codes:
“3.3”, “P1” and “P2”.