Internet Switch (EZI-10) Ver. 1.1
Sollae Systems Co., Ltd.
- 8 -
http://www.sollae.co.kr
3.2
Advanced Operation
You can use this application in detail by using the below parameters.
Figure 3-3 advanced operation
Valid Time
EZI-10 recognizes that the input signal is valid only if the signal keeps HIGH for the
value of [Valid Time]. That means all shorter signals than the value of [Valid Time] are
ignored. The unit is 10ms.
Notify Input Port Change
This option lets EZI-10 send response segments to the counterpart immediately when
its input port state has been changed without queries.
Delay
EZI-10 delays output as much as time set to the value of [Delay]. The output signal
should be maintained by the point of operation time and any other outputs can be
acceptable when timer is running by this option. The unit is 10ms.