2.2.1 

Setting TCP/IP Parameters 

Usually, a slave is set to a TCP server. (Modbus / Passive) 

 

In case that the master is set to a TCP server, the slave should be a TCP client. 

 

Figure 2-4 TCP/IP configuration of the slave 

①  Set the TCP/IP parameters. (Set parameters referring to the below table) 

Table 2-4 TCP/IP parameters of the slave 

Parameter 

Description 

Value 

Comm. Mode 

TCP Active or Passive connection 

Modbus / Passive 

Local Port 

Port number for communication 

502 

Allowed IP Address 

Allowed IP address for TCP connection 

0.0.0.0 

Master / Slave 

Mode selection 

Slave 

Unit ID 

ID of a pairs of a master and a slave 

Input Port Base Addr. 

Input Port Base Address 

Output Port Base Addr. 

Output Port Base Address 

②  Click the [Write] button. 

 

 

Summary of Contents for EZI-10

Page 1: ...Caution Specifications of this document may be changed without prior notice for improvement Sollae Systems Co Ltd http www sollae co kr ezTCP Technical Documents Internet Switch EZI 10 Version 1 1...

Page 2: ...ents 1 Overview 2 2 Configuration 3 2 1 Master 3 2 1 1 Setting Network Parameters 3 2 1 2 Setting TCP IP Parameters 4 2 2 Slave 5 2 2 1 Setting Network Parameters 5 2 2 1 Setting TCP IP Parameters 6 3...

Page 3: ...web browser You don t need to make an application The other one is Modbus TCP This way allows users to set some detailed and complicated operations To use Modbus TCP you should make an application or...

Page 4: ...your network environment 2 1 1 Setting Network Parameters ezConfigIO is the tool for configuring parameters of EZI 10 Connect EZI 10 to your network and run ezConfgIO on your PC Referring to the below...

Page 5: ...configuration of the master Set the TCP IP parameters Set parameters referring to the below table Table 2 2 TCP IP parameters Parameter Description Value Comm Mode TCP Active or Passive connection Mo...

Page 6: ...he same with the master s Figure 2 3 network configuration of the slave Press the Search All button Set network parameters Table 2 3 network parameters Parameter Description Value IP Assignment Automa...

Page 7: ...P IP parameters Set parameters referring to the below table Table 2 4 TCP IP parameters of the slave Parameter Description Value Comm Mode TCP Active or Passive connection Modbus Passive Local Port Po...

Page 8: ...co kr 3 Operation 3 1 Basic Operation There are two basic operations in this application Automatic Control of the Master s OUTPUT by the Slave s INPUT Figure 3 1 basic operation 1 Automatic Control of...

Page 9: ...ue of Valid Time That means all shorter signals than the value of Valid Time are ignored The unit is 10ms Notify Input Port Change This option lets EZI 10 send response segments to the counterpart imm...

Page 10: ...1 Sollae Systems Co Ltd 9 http www sollae co kr 4 Revision History Date Version Description Author 2011 04 07 1 0 This document has been initially released Roy LEE 2013 02 07 1 1 Update some figures s...

Reviews: