background image

SIG-5440 User Manual Ver. 1.0 

 

- 32 - 

https://www.ezTCP.com

 

 

 7

 

Precaution and Exemption from Liability 

7.1

 

 Precaution  

 

Sollae  Systems  is  not  responsible  for  product  failures  occurring  due  to 

user

s alternation of the product.  

 

Specifications of the product are subject to change without prior notice for 

performance improvement.  

 

Sollae Systems does not guarantee successful operation of the product if the 

product was used under conditions deviating from the product specifications.  

 

Reverse  engineering  of  firmware  and  applications  provided  by  Sollae  Systems 

is prohibited.  

 

Use  of  firmware  and  applications  provided  by  Sollae  Systems  for  purposes 

other than those for which they were designed is prohibited.  

 

Do not use the product in an extremely cold or hot place or in a place where 

vibration is severe.  

 

Do not use the product in an environment in which humidity is high or a lot 

of oil exists.  

 

Do not use the product where there is caustic or combustible gas.  

 

Sollae Systems does not guarantee normal operation of the product under the 

conditions a lot of noise exists.  

 

Do  not  use  the  product  for  a  purpose  that  requires  exceptional  quality  and 

reliability  relating  to  user

s  injuries  or  accidents 

  aerospace,  aviation, 

health care, nuclear power, transportation, and safety purposes.  

 

Sollae Systems is not responsible for any accident or damage occurring while 

using the product.  

 

 

Summary of Contents for SIG-5440

Page 1: ...Sollae Systems https www ezTCP com 4 Port Digital Input I O Gateway SIG 5440 User Manual Version 1 0...

Page 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused...

Page 3: ...13 2 3 Searching Devices 13 2 4 Logging in 13 3 Settings 14 3 1 Network 14 3 1 1 Obtain an IP address automatically 14 3 1 2 Use a Static IP address 15 3 2 General 16 3 2 1 Comments 16 3 2 2 TCP 16 3...

Page 4: ...d Digital Input Status Register 28 5 1 3 Digital Input Counter Register 28 5 1 4 Device Information Register 29 5 2 Read Write 30 5 2 1 Reset Counter Register 30 6 Technical Support and Warranty 31 6...

Page 5: ...onsisting of 4 digital input ports Users can remotely monitor digital values of sensors connected to this product by using Modbus TCP 1 2 Features 4 digital input ports Wet Contact or Dry Contact inpu...

Page 6: ...IPv4 IPv6 Dual Stack TCP UDP ICMP DHCP mDNS Modbus TCP SSL TLS Indicators LED MTX MRX Di0 Di1 Di2 Di3 Management spFinder Configuration and Monitoring Tool Security Password Dimension Size 94mm x 57mm...

Page 7: ...SIG 5440 User Manual Ver 1 0 6 https www ezTCP com 1 4 Interface Figure 1 1 Interface 1 4 1 Power SIG 5440 requires DC5V power supply whose specification is as follows Figure 1 2 Power...

Page 8: ...re 1 3 Ethernet 1 4 3 Digital Input Port This port is interfaced with a 3 5mm pitch 6 pole terminal block Figure 1 4 Digital Input Port Port Specification Division Value Number of ports 4 Maximum Inpu...

Page 9: ...SIG 5440 User Manual Ver 1 0 8 https www ezTCP com Circuit Diagram of Digital Input Figure 1 5 Circuit Diagram of Digital Input WET contact Figure 1 6 WET contact...

Page 10: ...SIG 5440 User Manual Ver 1 0 9 https www ezTCP com DRY contact Figure 1 7 DRY contact NPN transistor Figure 1 8 NPN transistor...

Page 11: ...SIG 5440 User Manual Ver 1 0 10 https www ezTCP com PNP transistor Figure 1 9 PNP transistor...

Page 12: ...as follows When the script is running RUN When the script is running RUN When a network is not connected LINK When a network is connected LINK When a TCP connection is NOT established MTX MRX When se...

Page 13: ...5440 User Manual Ver 1 0 12 https www ezTCP com 1 4 5 Function Button This button is used to implement a factory reset 1 4 6 Setup Port This port is used for making a connection with a PC via USB cab...

Page 14: ...LAN cable or a USB cable In the case of using a LAN cable note that your PC and the product should be on the same local area network 2 3 Searching Devices Run spFinder on your PC and press the search...

Page 15: ...IP address automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 3 1 Obtain an IP address automatically Select the Obtain an IP address...

Page 16: ...com 3 1 2 Use a Static IP address You can set a static IP address to this product Figure 3 2 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...

Page 17: ...o It is valid only when the Communication Mode is set to TCP Client Port This item is to set the port number for the TCP connection It can be set between 0 and 65535 The default is 502 Multiple Connec...

Page 18: ...You can choose one among three options Rise rising edge Fall falling edge and Both rising edge or falling edge The default value is Rise Valid Time Unit ms This item is to set the valid time of input...

Page 19: ...ick the Save button 3 3 2 Certificate This is NOT available for this product 3 3 3 spFinder These items are related to spFinder use Local search If this item is not checked you will not be able to sea...

Page 20: ...er 1 0 19 https www ezTCP com Remote access If this item is checked the product can be connected from the remote network For security this item is unchecked by default 3 3 4 Client ID This is NOT avai...

Page 21: ...ose the window or time out While the connection is maintained other hosts cannot access the product using the spFinder 4 1 1 Product Information Product Information Window This area shows some major i...

Page 22: ...ected host will be shown CONNECTING Connecting DISCONNECTING Disconnecting Table 4 2 TCP STATE MODBUS STATISTICS Item Description RX0 3 Statistics of incoming data from TCP Query Error Discard TX0 3 S...

Page 23: ...h input port Table 4 4 DEVICE STATISTICS 4 1 3 Timeout This is the timeout display function that appears in the upper right of the status window When this time reaches zero the connection between spFi...

Page 24: ...ou can upgrade it to the latest version Firmware can be upgraded online or manually via spFinder 4 2 1 Online Upgrade If you can access to the Internet by your PC the Firmware can be upgraded online F...

Page 25: ...4 4 Manual Upgrade Download a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click...

Page 26: ...until you close the window or time out While the connection is maintained other hosts cannot access the product using the spFinder Figure 4 5 Console 4 3 1 Output Tab This tab displays console messag...

Page 27: ...n the upper right of the console window When this time reaches zero the connection between spFinder and the product is lost The initial value is 30 minutes If you move the mouse pointer in the interna...

Page 28: ...the password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once...

Page 29: ...values The range of values is 0 to 4905 Division Address Bit Count Type Function Code HMI Addressing Example Port 0 80 1 Boolean 02 10081 Port 1 81 1 Boolean 02 10082 Port 2 82 1 Boolean 02 10083 Port...

Page 30: ...ss 442 6 ASCII 03 40443 IP Address 448 8 ASCII 03 40449 Table 5 4 Device Information Register Vendor Name This is the Vendor Name Product Code This is the product code Version Major Minor Revision Thi...

Page 31: ...the bit corresponding to each port is stored as 1 the counter value of the port is initialized and the bit is set to 0 again Division Address Bit Count Type Function Code HMI Addressing Example Port...

Page 32: ...com en support qna php 6 2 Warranty 6 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...

Page 33: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Page 34: ...ars planes trucks boats aircraft helicopters etc In the same way the SIG 5440 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...

Page 35: ...r utiliser le bo tier SIG 5440 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le bo tier SIG 5440 est exclusivement pr vu pour un usage en int ri...

Page 36: ...llae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier SIG 5440 puisse tre chang au titre de la garantie Rappel sur l vacuation des quipements lectroniques usag s...

Page 37: ...SIG 5440 User Manual Ver 1 0 36 https www ezTCP com 8 Revision History Date Version Description Author 2020 09 08 1 0 1 Created Roy Lee...

Reviews: